Furnace
Bryant 926TC60100V21
- Category
- Furnace
- Series
- Not assigned in catalog
- Model record
- Exact model
- Certifications
- 160 linked
Canonical product data
Specifications
Product specifications
- Fuel Type
- Natural Gas,Propane Gas
- Hot Water Integration Capable
- No
- Market Availability
- Canada, United States
- Afue (Mode: space_heating)
- 96.1 %
Matched systems
Certificates
159 verified catalog relationships.
AHRI 215619841
AHRI 215619841 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN036**AA* and indoor unit CVAMA4821XMA*.
AHRI 215619842
AHRI 215619842 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit GH8TAN536**AA* and indoor unit CVAMA4821XMA*.
AHRI 215619843
AHRI 215619843 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit PH8TAN536**AA* and indoor unit CVAMA4821XMA*.
AHRI 215620078
AHRI 215620078 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN036**AA* and indoor unit CVAMA4921XMA*.
AHRI 215620079
AHRI 215620079 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit GH8TAN536**AA* and indoor unit CVAMA4921XMA*.
AHRI 215620080
AHRI 215620080 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit PH8TAN536**AA* and indoor unit CVAMA4921XMA*.
AHRI 215621225
AHRI 215621225 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit 248TAN036**AA* and indoor unit CVAVA3721XMA*.
AHRI 215621226
AHRI 215621226 identifies a HP - Split System from BRYANT HEATING AND COOLING SYSTEMS with outdoor unit GH8TAN536**AA* and indoor unit CVAVA3721XMA*.
Source-backed diagnostics
Error codes
45 codes matched to Bryant 926TC60100V21 through its documented series or control platform.
L1 polarity fault
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
W on at power up
Record the code, check the thermostat and filter, and schedule service if the condition remains.
Limit lockout - switch open longer than 3 minutes in Main Limit circuit
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Ignition lockout after 4 consecutive ignition tries
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Flame lost 3 times after 70s of heating
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.
Lockout - 7 loss of flame events during a heat request
Record the code, avoid repeated reset attempts, and schedule GreenFlow service.