ENERGY STAR AHRI details

American Standard 4A6V0X36A1

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandAmerican Standard
Outdoor unit model4A6V0X36A1
Indoor unit models4PX*CU36BS3
Furnace model*UD2C100ACV5
Model namePLATINUM 20
Model number4A6V0X36A1

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
34600
Heating Capacity 47F (BTUH)
31600
Heating Capacity 17F (BTUH)
26400
Heating Capacity 5F (BTUH)
20400
Seer2
20.00
HSPF2 Region IV
8.50
EER2 AFull 95F
12.00
COP at 5F
1.81
Refrigerant Type
R-410A

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
No

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Same cooling capacity

Trane

Split-system heat pump

4TWV0X36A1 — Trane AHRI 207558969

AHRI 207558969

Indoor model / pattern
4PX*CU36BS3
Furnace model / pattern
*UD2C100ACV5
Cooling · BTU/h
34,600
SEER2
20.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.
View AHRI
Same cooling capacity

Trane

Split-system heat pump

5TWR5036A1 — Trane AHRI 215568480

AHRI 215568480

Indoor model / pattern
5PX*C007AS3+TSTAT
Furnace model / pattern
S9V2C100U5PSC
Cooling · BTU/h
34,600
SEER2
16.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 16.00 vs. 20.00
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 17°F: 22,200 BTU/h.
  • Lower heating capacity at 5°F: 17,700 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27VNA036A*030* — Carrier AHRI 215670446

AHRI 215670446

Indoor model / pattern
CSAH*6012AM*+UI
Furnace model / pattern
58TN*B090C21**20
Cooling · BTU/h
34,600
SEER2
17.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 17.00 vs. 20.00
  • Different refrigerant: R-454B (current: R-410A).
View AHRI
Higher SEER2

Carrier

Split-system heat pump

27VNA336A*030* — Carrier AHRI 215932894

AHRI 215932894

Indoor model / pattern
CAA**6124AM*+UI
Furnace model / pattern
59CU5B100C21**22
Cooling · BTU/h
34,600
SEER2
20.50
HSPF2
9.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 20.50 vs. 20.00
  • Different refrigerant: R-454B (current: R-410A).
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL19KPV-036-230A** — Lennox AHRI 217194388

AHRI 217194388

Indoor model / pattern
CK40HT-36C-**+TDR
Furnace model / pattern
SL297UH080NV48C*
Cooling · BTU/h
34,600
SEER2
17.50
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.10 vs. 8.50
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 17°F: 21,000 BTU/h.
  • Lower heating capacity at 5°F: 16,500 BTU/h.
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL18KSLV-036-230A** — Lennox AHRI 217189823

AHRI 217189823

Indoor model / pattern
CK40[C,U]T-36B-**+TDR
Furnace model / pattern
SL280UH090V48B*
Cooling · BTU/h
34,600
SEER2
18.10
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 18.10 vs. 20.00
  • Different refrigerant: R-454B (current: R-410A).
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service

Popular cities

Service Areas