ENERGY STAR AHRI details

Trane 4TWV8X48A1

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandTrane
Outdoor unit model4TWV8X48A1
Indoor unit modelsTEM8B0C60V51+TDR
Model nameXV18I
Model number4TWV8X48A1

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
47000
Heating Capacity 47F (BTUH)
43000
Heating Capacity 17F (BTUH)
36600
Heating Capacity 5F (BTUH)
28600
Seer2
18.00
HSPF2 Region IV
8.50
EER2 AFull 95F
12.00
COP at 5F
1.94
Refrigerant Type
R-410A

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
No

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Same outdoor unit

Trane

Split-system heat pump

4TWV8X48A1 — Trane AHRI 207526358

AHRI 207526358

Indoor model / pattern
TEM8A0C48V41+TDR
Cooling · BTU/h
47,000
SEER2
18.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySame outdoor unit, different indoor combination.
View AHRI
Same brand

Trane

Split-system heat pump

4TWV7X48A1 — Trane AHRI 214671738

AHRI 214671738

Indoor model / pattern
TEM8A0C48V41+TDR+LRP
Cooling · BTU/h
47,000
SEER2
17.10
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 17.10 vs. 18.00
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27TPA848A**30* — Carrier AHRI 215628597

AHRI 215628597

Indoor model / pattern
CVAVA4821XMA*+TDR
Cooling · BTU/h
47,000
SEER2
16.00
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.00 vs. 8.50
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 17°F: 30,000 BTU/h.
  • Lower heating capacity at 5°F: 23,800 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

GH8TAN548**AA* — Carrier AHRI 215628598

AHRI 215628598

Indoor model / pattern
CVAVA4821XMA*+TDR
Cooling · BTU/h
47,000
SEER2
16.00
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.00 vs. 8.50
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 17°F: 30,000 BTU/h.
  • Lower heating capacity at 5°F: 23,800 BTU/h.
View AHRI
Higher SEER2

Lennox

Split-system heat pump

EL21KLV-048-230A** — Lennox AHRI 217121638

AHRI 217121638

Indoor model / pattern
CBK47UHET-060-230-**
Cooling · BTU/h
47,000
SEER2
18.50
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 18.50 vs. 18.00
  • Different refrigerant: R-454B (current: R-410A).
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

ML17XP1-048-230A** — Lennox AHRI 210051035

AHRI 210051035

Indoor model / pattern
CBA25UHV-048-230-**
Cooling · BTU/h
47,000
SEER2
15.20
HSPF2
8.30

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.30 vs. 8.50
  • Lower heating capacity at 17°F: 30,400 BTU/h.
  • Lower heating capacity at 5°F: 24,200 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service

Popular cities

Service Areas