ENERGY STAR AHRI details

Ruud UP18AZ36AJVC

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandRuud
Outdoor unit modelUP18AZ36AJVC
Indoor unit modelsRCFZ6021SEAAM
Furnace modelU98MV1005A21UPS
Model nameULTRA SERIES
Model numberUP18AZ36AJVC

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
34200
Heating Capacity 47F (BTUH)
36000
Heating Capacity 17F (BTUH)
41000
Heating Capacity 5F (BTUH)
43500
Seer2
19.00
HSPF2 Region IV
8.50
EER2 AFull 95F
12.50
COP at 5F
2.20
Refrigerant Type
R-410A

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
Yes

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Higher SEER2

Carrier

Split-system heat pump

27VNA336A*030* — Carrier AHRI 215935714

AHRI 215935714

Indoor model / pattern
CVAVA3621XMA*+UI
Furnace model / pattern
59MN7C060C21**20
Cooling · BTU/h
34,200
SEER2
20.50
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 20.50 vs. 19.00
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 17°F: 32,600 BTU/h.
  • Lower heating capacity at 5°F: 28,600 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27VPA936A*030* — Carrier AHRI 217908536

AHRI 217908536

Indoor model / pattern
CAA**4221AM*
Furnace model / pattern
58SP*B070V17**16
Cooling · BTU/h
34,200
SEER2
15.20
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 15.20 vs. 19.00
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 17°F: 36,200 BTU/h.
  • Lower heating capacity at 5°F: 25,600 BTU/h.
View AHRI
Same cooling capacity

Bosch

Split-system heat pump

BOVB-36MTB-M19E — Bosch AHRI 217903134

AHRI 217903134

Indoor model / pattern
BMAC4248BBTA
Furnace model / pattern
BGH96M080B3C
Cooling · BTU/h
34,200
SEER2
18.00
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 18.00 vs. 19.00
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 17°F: 34,600 BTU/h.
  • Lower heating capacity at 5°F: 33,000 BTU/h.
View AHRI
Similar cooling capacity

Bosch

Split-system heat pump

BOHA-36MTB-M18S — Bosch AHRI 218032194

AHRI 218032194

Indoor model / pattern
BMAC3036CBTA
Furnace model / pattern
BGH97M080C4A
Cooling · BTU/h
34,000
SEER2
16.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity −0.6%Similar cooling capacity.Lower SEER2: 16.00 vs. 19.00
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 17°F: 29,000 BTU/h.
  • Lower heating capacity at 5°F: 36,000 BTU/h.
View AHRI
Same cooling capacity

Fujitsu

Split-system heat pump

FOP1836MJAZCA — Fujitsu AHRI 210868912

AHRI 210868912

Indoor model / pattern
FCCA6021SZEA
Furnace model / pattern
FF75214LT80Y
Cooling · BTU/h
34,200
SEER2
19.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.
View AHRI
Same cooling capacity

Fujitsu

Split-system heat pump

WP15AY36AJ2N — Fujitsu AHRI 216685541

AHRI 216685541

Indoor model / pattern
FCCN3621SYTA
Furnace model / pattern
FF95SV510021UH
Cooling · BTU/h
34,200
SEER2
15.20
HSPF2
7.80

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 7.80 vs. 8.50
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 17°F: 33,200 BTU/h.
  • Lower heating capacity at 5°F: 18,500 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.