ENERGY STAR AHRI details

Armstrong Air 4SHP17LE130P-**A

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandArmstrong Air
Outdoor unit model4SHP17LE130P-**A
Indoor unit modelsEA(C;U)1P30A+TDR+TXV
Furnace modelA80UH1E045A12
Model name4SHP17LE SERIES
Model number4SHP17LE130P-**A

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
28600
Heating Capacity 47F (BTUH)
27600
Heating Capacity 17F (BTUH)
18000
Heating Capacity 5F (BTUH)
14100
Seer2
15.80
HSPF2 Region IV
8.00
EER2 AFull 95F
13.00
COP at 5F
2.20
Refrigerant Type
R-410A

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
No

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Same cooling capacity

Trane

Split-system heat pump

5TWX5030A1 — Trane AHRI 215686672

AHRI 215686672

Indoor model / pattern
5PX*CD07AS3+TSTAT
Furnace model / pattern
S8V2C100M5PCB
Cooling · BTU/h
28,600
SEER2
15.50
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 15.50 vs. 15.80
  • Different refrigerant: R-454B (current: R-410A).
View AHRI
Higher SEER2

Trane

Split-system heat pump

5TWR6030A1 — Trane AHRI 218395222

AHRI 218395222

Indoor model / pattern
5PX*B006AS3+TSTAT
Furnace model / pattern
S9X1B040U3PSB
Cooling · BTU/h
28,600
SEER2
16.00
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 16.00 vs. 15.80
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 47°F: 26,000 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

37MUHAQ30AA3+TIC2025-0016 — Carrier AHRI 217383657

AHRI 217383657

Indoor model / pattern
CAA**3617AM*
Furnace model / pattern
58S(B,C)*B070M14**12
Cooling · BTU/h
28,600
SEER2
15.50
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 15.50 vs. 15.80
  • Different refrigerant: R-454B (current: R-410A).
View AHRI
Similar cooling capacity

Carrier

Split-system heat pump

27SPA631A**30* — Carrier AHRI 217691444

AHRI 217691444

Indoor model / pattern
CAA**3721AM*
Furnace model / pattern
59TP6C100V21**22
Cooling · BTU/h
29,200
SEER2
15.50
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity +2.1%Similar cooling capacity.Lower SEER2: 15.50 vs. 15.80
  • Different refrigerant: R-454B (current: R-410A).
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

ML17XP1-030-230A** — Lennox AHRI 210046744

AHRI 210046744

Indoor model / pattern
C35-30A+TDR+TXV
Furnace model / pattern
ML180UH045E36A*
Cooling · BTU/h
28,600
SEER2
15.80
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL17XP1-030-230A** — Lennox AHRI 210291549

AHRI 210291549

Indoor model / pattern
C35-30A+TDR+TXV
Furnace model / pattern
ML180UH045E36A*
Cooling · BTU/h
28,600
SEER2
15.80
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service

Popular cities

Service Areas