ENERGY STAR AHRI details

Fraser-Johnston THF2B36T21

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandFraser-Johnston
Outdoor unit modelTHF2B36T21
Indoor unit modelsXAHD48FBCN1+JMVT20DC2N1
Model nameLX SERIES
Model numberTHF2B36T21

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
36000
Heating Capacity 47F (BTUH)
34000
Heating Capacity 17F (BTUH)
22000
Heating Capacity 5F (BTUH)
17200
Seer2
16.00
HSPF2 Region IV
8.10
EER2 AFull 95F
12.00
COP at 5F
2.14
Refrigerant Type
R-410A

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
No

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Higher SEER2

Trane

Split-system heat pump

5TWV0X36A1 — Trane AHRI 217179593

AHRI 217179593

Indoor model / pattern
5PX*CD09AS3+P0V0B000M40SD+LRP
Cooling · BTU/h
36,000
SEER2
20.00
HSPF2
9.40

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 20.00 vs. 16.00
  • Different refrigerant: R-454B (current: R-410A).
View AHRI
Higher SEER2

Trane

Split-system heat pump

4TWV0X36A1 — Trane AHRI 207690033

AHRI 207690033

Indoor model / pattern
TAMXA0C42V41
Cooling · BTU/h
35,600
SEER2
20.50
HSPF2
8.70

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity −1.1%Similar cooling capacity.Higher SEER2: 20.50 vs. 16.00
  • Heating capacity comparison at 5°F unavailable.
View AHRI
Higher SEER2

Carrier

Split-system heat pump

27TPA836A**30* — Carrier AHRI 215628934

AHRI 215628934

Indoor model / pattern
FT5ANBD60L*
Cooling · BTU/h
36,000
SEER2
17.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 17.00 vs. 16.00
  • Different refrigerant: R-454B (current: R-410A).
View AHRI
Higher SEER2

Carrier

Split-system heat pump

GH8TAN536**AA* — Carrier AHRI 215628936

AHRI 215628936

Indoor model / pattern
FT5ANBD60L*
Cooling · BTU/h
36,000
SEER2
17.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 17.00 vs. 16.00
  • Different refrigerant: R-454B (current: R-410A).
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

ML17XP1-036-230A** — Lennox AHRI 210048676

AHRI 210048676

Indoor model / pattern
CBA25UHV-036-230-**
Cooling · BTU/h
36,000
SEER2
15.80
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 15.80 vs. 16.00
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL17XP1-036-230A** — Lennox AHRI 210293445

AHRI 210293445

Indoor model / pattern
CBA25UHV-036-230-**
Cooling · BTU/h
36,000
SEER2
15.80
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 15.80 vs. 16.00
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service