ENERGY STAR AHRI details

BRYANT HEATING AND COOLING SYSTEMS 288BNV037*0**B*+TSTAT

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit model288BNV037*0**B*+TSTAT
Indoor unit modelsCNPV*6024AL*
Furnace model926TB60080V21***
Model nameEVOLUTION V Heat Pump 2-STAGE
Model number288BNV037*0**B*+TSTAT

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
32400
Heating Capacity 47F (BTUH)
47500
Heating Capacity 17F (BTUH)
30800
Heating Capacity 5F (BTUH)
24400
Seer2
17.50
HSPF2 Region IV
8.10
EER2 AFull 95F
11.70
COP at 5F
1.96
Refrigerant Type
R-410A

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
No

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Same cooling capacity

Carrier

Split-system heat pump

25VNA837A*031*+TSTAT — Carrier AHRI 210465135

AHRI 210465135

Indoor model / pattern
CNPV*6024AL*
Furnace model / pattern
59TP6B080V21**20
Cooling · BTU/h
32,400
SEER2
17.50
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.
View AHRI
Higher SEER2

Carrier

Split-system heat pump

27VNA336A*030* — Carrier AHRI 215939604

AHRI 215939604

Indoor model / pattern
CAA**3617AM*+UI
Furnace model / pattern
58CU*B040C17**12
Cooling · BTU/h
32,400
SEER2
19.50
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 19.50 vs. 17.50
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 47°F: 35,000 BTU/h.
View AHRI
Similar cooling capacity

Bosch

Split-system heat pump

BOHA-36RTB-M18S — Bosch AHRI 218032223

AHRI 218032223

Indoor model / pattern
BMAC3036ABTA
Furnace model / pattern
BGH97M060B3A
Cooling · BTU/h
32,600
SEER2
16.00
HSPF2
8.20

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity +0.6%Similar cooling capacity.Lower SEER2: 16.00 vs. 17.50
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 47°F: 34,200 BTU/h.
  • Lower heating capacity at 17°F: 29,000 BTU/h.
View AHRI
Similar cooling capacity

Bosch

Split-system heat pump

BOHA-36MTB-M18S — Bosch AHRI 218032187

AHRI 218032187

Indoor model / pattern
BMAC3036ABTA
Furnace model / pattern
BGH97M060B3A
Cooling · BTU/h
32,600
SEER2
16.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity +0.6%Similar cooling capacity.Lower SEER2: 16.00 vs. 17.50
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 47°F: 34,200 BTU/h.
  • Lower heating capacity at 17°F: 29,000 BTU/h.
View AHRI
Similar cooling capacity

Fujitsu

Split-system heat pump

WP15AY36AJ2N — Fujitsu AHRI 216685541

AHRI 216685541

Indoor model / pattern
FCCN3621SYTA
Furnace model / pattern
FF95SV510021UH
Cooling · BTU/h
34,200
SEER2
15.20
HSPF2
7.80

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity +5.6%Similar cooling capacity.Lower HSPF2 (Region IV): 7.80 vs. 8.10
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 47°F: 34,200 BTU/h.
  • Lower heating capacity at 5°F: 18,500 BTU/h.
View AHRI
Similar cooling capacity

Fujitsu

Split-system heat pump

FOP1536TJAYNA — Fujitsu AHRI 216686392

AHRI 216686392

Indoor model / pattern
FCCN3621SYTA
Furnace model / pattern
FF95SV510021UH
Cooling · BTU/h
34,200
SEER2
15.20
HSPF2
7.80

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity +5.6%Similar cooling capacity.Lower HSPF2 (Region IV): 7.80 vs. 8.10
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 47°F: 34,200 BTU/h.
  • Lower heating capacity at 5°F: 18,500 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Brands We Service