ENERGY STAR AHRI details

Goodman GSZC703610A*

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandGoodman
Outdoor unit modelGSZC703610A*
Indoor unit modelsCAPTA4230*4A*
Furnace modelG*VC961005CNB*
Model nameGSZC7
Model numberGSZC703610A*

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
34800
Heating Capacity 47F (BTUH)
34000
Heating Capacity 17F (BTUH)
21000
Heating Capacity 5F (BTUH)
17000
Seer2
17.20
HSPF2 Region IV
8.10
EER2 AFull 95F
12.50
COP at 5F
2.00
Refrigerant Type
R-410A

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
No

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Same cooling capacity

Trane

Split-system heat pump

5TWX5036A1 — Trane AHRI 215687015

AHRI 215687015

Indoor model / pattern
5PX*C009AS3+TSTAT
Furnace model / pattern
L8V1C100U5VSB
Cooling · BTU/h
34,800
SEER2
16.50
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 16.50 vs. 17.20
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 47°F: 31,200 BTU/h.
View AHRI
Same cooling capacity

Trane

Split-system heat pump

5TWR5036A1 — Trane AHRI 214078781

AHRI 214078781

Indoor model / pattern
5TXCD010AS3+TSTAT
Furnace model / pattern
S9V2D120U5PSC
Cooling · BTU/h
34,800
SEER2
16.00
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 16.00 vs. 17.20
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 47°F: 31,200 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

25SCA536A**30* — Carrier AHRI 210313427

AHRI 210313427

Indoor model / pattern
CAP**3721AL*
Furnace model / pattern
58S(B,C)*A090E21**20
Cooling · BTU/h
34,800
SEER2
15.20
HSPF2
7.80

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 7.80 vs. 8.10
  • Lower heating capacity at 5°F: 15,800 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27SCA536A**30* — Carrier AHRI 214138223

AHRI 214138223

Indoor model / pattern
CAA**3721AM*
Furnace model / pattern
58S(B,C)*B090M21**20
Cooling · BTU/h
34,800
SEER2
15.20
HSPF2
7.80

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 7.80 vs. 8.10
  • Different refrigerant: R-454B (current: R-410A).
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL19KPV-036-230A** — Lennox AHRI 217446759

AHRI 217446759

Indoor model / pattern
CK40DT-30/36C-**+TDR
Furnace model / pattern
SLP99DF090XV36C*
Cooling · BTU/h
34,800
SEER2
17.00
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 17.00 vs. 17.20
  • Different refrigerant: R-454B (current: R-410A).
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

ML16KP2-036-230A** — Lennox AHRI 218457628

AHRI 218457628

Indoor model / pattern
CK40HT-36C-**+TDR
Furnace model / pattern
ML193UH070XE36B*
Cooling · BTU/h
34,800
SEER2
15.50
HSPF2
8.20

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 15.50 vs. 17.20
  • Different refrigerant: R-454B (current: R-410A).
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service

Popular cities

Service Areas