ENERGY STAR AHRI details

Lennox ML17XP1-048-230A**

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandLennox
Outdoor unit modelML17XP1-048-230A**
Indoor unit modelsC35-48C+TDR+TXV
Furnace modelEL297UH090XV36C*
Model nameMERIT ML17XP1 Series
Model numberML17XP1-048-230A**

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
46000
Heating Capacity 47F (BTUH)
44500
Heating Capacity 17F (BTUH)
30200
Heating Capacity 5F (BTUH)
24400
Seer2
15.20
HSPF2 Region IV
8.00
EER2 AFull 95F
12.50
COP at 5F
2.18
Refrigerant Type
R-410A

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
No

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Higher SEER2

Trane

Split-system heat pump

4TWV7X48A1 — Trane AHRI 215825811

AHRI 215825811

Indoor model / pattern
4PX*DU60BS3
Furnace model / pattern
S9V2C100U5VSB+LRP
Cooling · BTU/h
46,000
SEER2
17.00
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 17.00 vs. 15.20
View AHRI
Higher SEER2

Trane

Split-system heat pump

4TWV8X48A1 — Trane AHRI 215825905

AHRI 215825905

Indoor model / pattern
4PX*DU60BS3
Furnace model / pattern
S9V2C080U5VSB+RP
Cooling · BTU/h
46,000
SEER2
18.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 18.00 vs. 15.20
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27TPA848A**30* — Carrier AHRI 215633733

AHRI 215633733

Indoor model / pattern
CSAH*4812AM*
Furnace model / pattern
59SP6B120V24**22
Cooling · BTU/h
46,000
SEER2
15.20
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.
  • Different refrigerant: R-454B (current: R-410A).
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

GH8TAN548**AA* — Carrier AHRI 215633734

AHRI 215633734

Indoor model / pattern
CSAH*4812AM*
Furnace model / pattern
59SP6B120V24**22
Cooling · BTU/h
46,000
SEER2
15.20
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.
  • Different refrigerant: R-454B (current: R-410A).
View AHRI
Same outdoor unit

Lennox

Split-system heat pump

ML17XP1-048-230A** — Lennox AHRI 210050925

AHRI 210050925

Indoor model / pattern
C35-48C+TDR+TXV
Furnace model / pattern
SLP99UH090XV36C*
Cooling · BTU/h
46,000
SEER2
15.20
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySame outdoor unit, different indoor combination.
View AHRI
Same brand

Lennox

Split-system heat pump

ML16KP2-048-230A** — Lennox AHRI 218457816

AHRI 218457816

Indoor model / pattern
CK40HT-60D-**+TDR
Furnace model / pattern
SL297UH080NV60C*
Cooling · BTU/h
46,000
SEER2
16.00
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 16.00 vs. 15.20
  • Different refrigerant: R-454B (current: R-410A).
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service

Popular cities

Service Areas