ENERGY STAR AHRI details

Wells WUCA-36HFMO

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandWells
Outdoor unit modelWUCA-36HFMO
Indoor unit modelsWUA-36BHFM
Model nameWUA Series
Model numberWUCA-36HFMO

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
35000
Heating Capacity 47F (BTUH)
38000
Heating Capacity 17F (BTUH)
27400
Heating Capacity 5F (BTUH)
31600
Seer2
15.50
HSPF2 Region IV
8.60
EER2 AFull 95F
10.00
COP at 5F
1.85
Refrigerant Type
R-410A

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
Yes

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Higher SEER2

Trane

Split-system heat pump

4TWV0X36A1 — Trane AHRI 210929563

AHRI 210929563

Indoor model / pattern
TAMXB0C36V31
Cooling · BTU/h
35,000
SEER2
19.50
HSPF2
8.70

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 19.50 vs. 15.50
  • Lower heating capacity at 47°F: 31,600 BTU/h.
  • Lower heating capacity at 17°F: 26,000 BTU/h.
  • Lower heating capacity at 5°F: 20,000 BTU/h.
View AHRI
Same cooling capacity

Trane

Split-system heat pump

5TWR5036A1 — Trane AHRI 215610941

AHRI 215610941

Indoor model / pattern
5TEM4D07AC51+TDR+TSTAT
Cooling · BTU/h
35,000
SEER2
15.20
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.10 vs. 8.60
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 47°F: 31,400 BTU/h.
  • Lower heating capacity at 17°F: 21,600 BTU/h.
  • Lower heating capacity at 5°F: 17,300 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

38MURAQ36AB3 — Carrier AHRI 213372208

AHRI 213372208

Indoor model / pattern
40MULAQ36XBX + CI
Cooling · BTU/h
35,000
SEER2
15.50
HSPF2
8.60

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.
View AHRI
Higher SEER2

Carrier

Split-system heat pump

37MUHAQ36AA3+TIC2025-0016 — Carrier AHRI 217382136

AHRI 217382136

Indoor model / pattern
FT5AN(B,X)C36L*
Cooling · BTU/h
35,000
SEER2
16.50
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.50 vs. 8.60
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 17°F: 25,400 BTU/h.
View AHRI
Higher SEER2

Lennox

Split-system heat pump

EL18KSLV-036-230A** — Lennox AHRI 216618913

AHRI 216618913

Indoor model / pattern
CBK48MVT-036-230-**
Cooling · BTU/h
35,000
SEER2
18.50
HSPF2
9.40

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 18.50 vs. 15.50
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 47°F: 36,000 BTU/h.
  • Lower heating capacity at 5°F: 29,400 BTU/h.
View AHRI
Higher SEER2

Lennox

Split-system heat pump

ML17XP1-036-230A** — Lennox AHRI 212510941

AHRI 212510941

Indoor model / pattern
CBA25UHE-036-230-**
Cooling · BTU/h
35,000
SEER2
15.80
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.00 vs. 8.60
  • Lower heating capacity at 47°F: 33,400 BTU/h.
  • Lower heating capacity at 17°F: 21,800 BTU/h.
  • Lower heating capacity at 5°F: 17,100 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service

Popular cities

Service Areas