ENERGY STAR AHRI details

Friedrich WFPU18Z483C

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandFriedrich
Outdoor unit modelWFPU18Z483C
Indoor unit modelsWFH48Z223C
Model nameBreeze
Model numberWFPU18Z483C

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
48000
Heating Capacity 47F (BTUH)
47000
Heating Capacity 17F (BTUH)
31000
Heating Capacity 5F (BTUH)
33000
Seer2
17.50
HSPF2 Region IV
8.50
EER2 AFull 95F
10.10
COP at 5F
1.90
Refrigerant Type
R-410A

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
Yes

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Same cooling capacity

Trane

Split-system heat pump

4TXD2060A10NU** — Trane AHRI 208141271

AHRI 208141271

Indoor model / pattern
4MXA2048A10NU**
Cooling · BTU/h
48,000
SEER2
17.00
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 17.00 vs. 17.50
View AHRI
Same cooling capacity

Trane

Split-system heat pump

5HCL5060A1 — Trane AHRI 216772257

AHRI 216772257

Indoor model / pattern
5TEM5D06AC41
Cooling · BTU/h
48,000
SEER2
17.00
HSPF2
9.40

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 17.00 vs. 17.50
  • Different refrigerant: R-454B (current: R-410A).
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

37MURAQ48AA3 — Carrier AHRI 215318759

AHRI 215318759

Indoor model / pattern
45MUAAQ48XX3
Cooling · BTU/h
48,000
SEER2
16.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 16.00 vs. 17.50
  • Different refrigerant: R-454B (current: R-410A).
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27TPA848A**30* — Carrier AHRI 215628521

AHRI 215628521

Indoor model / pattern
CVAMA4921XMA*+TDR
Cooling · BTU/h
48,000
SEER2
16.50
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.00 vs. 8.50
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 5°F: 24,000 BTU/h.
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL19KPV-048-230A** — Lennox AHRI 217446749

AHRI 217446749

Indoor model / pattern
CBK47UHET-060-230-**
Cooling · BTU/h
48,000
SEER2
17.50
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.
  • Different refrigerant: R-454B (current: R-410A).
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

ML16KP2-048-230A** — Lennox AHRI 218457822

AHRI 218457822

Indoor model / pattern
CBK43UHET-060-DV-**
Cooling · BTU/h
48,000
SEER2
16.00
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.10 vs. 8.50
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 5°F: 24,400 BTU/h.
View AHRI