ENERGY STAR AHRI details

American Standard 4A6V0X60A1

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandAmerican Standard
Outdoor unit model4A6V0X60A1
Indoor unit models4TXCD010DS3
Furnace model*UHMD120CCV5
Model namePLATINUM 20
Model number4A6V0X60A1

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
53500
Heating Capacity 47F (BTUH)
51000
Heating Capacity 17F (BTUH)
49000
Heating Capacity 5F (BTUH)
39000
Seer2
19.00
HSPF2 Region IV
8.20
EER2 AFull 95F
11.70
COP at 5F
1.80
Refrigerant Type
R-410A

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
Yes

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Same cooling capacity

Trane

Split-system heat pump

4TWV8X60A1 — Trane AHRI 213825966

AHRI 213825966

Indoor model / pattern
4TXCD010DS3
Furnace model / pattern
*UHMD120CCV5
Cooling · BTU/h
53,500
SEER2
18.00
HSPF2
8.20

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 18.00 vs. 19.00
View AHRI
Same cooling capacity

Trane

Split-system heat pump

4TWV7X60A1 — Trane AHRI 213826785

AHRI 213826785

Indoor model / pattern
4TXCD010DS3
Furnace model / pattern
*UHMD120CCV5+LRP
Cooling · BTU/h
53,500
SEER2
17.10
HSPF2
8.20

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 17.10 vs. 19.00
View AHRI
Higher SEER2

Carrier

Split-system heat pump

27VNA154A*030* — Carrier AHRI 215588497

AHRI 215588497

Indoor model / pattern
CVAMA6124XMA*+UI
Furnace model / pattern
58CU*B080C21**20
Cooling · BTU/h
53,500
SEER2
20.00
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.10 vs. 8.20
  • Different refrigerant: R-454B (current: R-410A).
View AHRI
Similar cooling capacity

Carrier

Split-system heat pump

27VPA960A*030* — Carrier AHRI 217908177

AHRI 217908177

Indoor model / pattern
CVAMA6021XMA*
Furnace model / pattern
58SU*B060M17**16
Cooling · BTU/h
54,000
SEER2
16.00
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity +0.9%Similar cooling capacity.Lower HSPF2 (Region IV): 8.00 vs. 8.20
  • Different refrigerant: R-454B (current: R-410A).
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL18KSLV-060-230A** — Lennox AHRI 217450084

AHRI 217450084

Indoor model / pattern
CK40HT-60D-**+TDR
Furnace model / pattern
SL280UH135V60D*
Cooling · BTU/h
53,500
SEER2
16.50
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 16.50 vs. 19.00
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 17°F: 43,500 BTU/h.
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL21KLV-060-230A** — Lennox AHRI 217121525

AHRI 217121525

Indoor model / pattern
CK40[C,U]T-60D-**+TDR
Furnace model / pattern
EL297UH135XE60D*
Cooling · BTU/h
53,500
SEER2
18.50
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 18.50 vs. 19.00
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 17°F: 40,500 BTU/h.
  • Lower heating capacity at 5°F: 34,600 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service

Popular cities

Service Areas