ENERGY STAR AHRI details

ECOER EODA19H-2436AA*

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandECOER
Outdoor unit modelEODA19H-2436AA*
Indoor unit modelsGNC2430APT
Furnace modelMGH96M080B3A
Model nameTDi Pro
Model numberEODA19H-2436AA*

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
23800
Heating Capacity 47F (BTUH)
24000
Heating Capacity 17F (BTUH)
22400
Heating Capacity 5F (BTUH)
19200
Seer2
18.50
HSPF2 Region IV
9.00
EER2 AFull 95F
12.00
COP at 5F
2.00
Refrigerant Type
R-410A

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
Yes

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Same cooling capacity

Trane

Split-system heat pump

5TWX7024A1 — Trane AHRI 216764132

AHRI 216764132

Indoor model / pattern
5PX*B006AS3
Furnace model / pattern
L8V1A060U3VSB
Cooling · BTU/h
23,800
SEER2
18.00
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 18.00 vs. 18.50
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 47°F: 22,000 BTU/h.
  • Lower heating capacity at 17°F: 15,500 BTU/h.
  • Lower heating capacity at 5°F: 17,500 BTU/h.
View AHRI
Same cooling capacity

Trane

Split-system heat pump

5TWR7024A1 — Trane AHRI 216765832

AHRI 216765832

Indoor model / pattern
5PX*B006AS3
Furnace model / pattern
S8V2A040M3PDB
Cooling · BTU/h
23,800
SEER2
17.10
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 17.10 vs. 18.50
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 47°F: 22,000 BTU/h.
  • Lower heating capacity at 17°F: 15,600 BTU/h.
  • Lower heating capacity at 5°F: 17,500 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27VPA924A*030* — Carrier AHRI 217933938

AHRI 217933938

Indoor model / pattern
CVAMA2417XMA*
Furnace model / pattern
58CU*B040C17**12
Cooling · BTU/h
23,800
SEER2
18.50
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.50 vs. 9.00
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 17°F: 20,200 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27VNA024A*030* — Carrier AHRI 215683671

AHRI 215683671

Indoor model / pattern
CAA**3717AM*+UI
Furnace model / pattern
58TN*B070C14**12
Cooling · BTU/h
23,800
SEER2
17.50
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 17.50 vs. 18.50
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 17°F: 19,800 BTU/h.
  • Lower heating capacity at 5°F: 16,500 BTU/h.
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL21KLV-024-230A** — Lennox AHRI 217443151

AHRI 217443151

Indoor model / pattern
CK40HT-30B-**+TDR
Furnace model / pattern
EL196UH045XE36B*
Cooling · BTU/h
23,800
SEER2
18.50
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 17°F: 21,000 BTU/h.
  • Lower heating capacity at 5°F: 17,300 BTU/h.
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL18KSLV-024-230A** — Lennox AHRI 216769564

AHRI 216769564

Indoor model / pattern
CK40[C,U]T-30B-**+TDR
Furnace model / pattern
SL297UH040NV36B*
Cooling · BTU/h
23,800
SEER2
17.45
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 17.45 vs. 18.50
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 17°F: 19,800 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service

Popular cities

Service Areas