ENERGY STAR AHRI details

American Standard 4A6V0X36A1

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandAmerican Standard
Outdoor unit model4A6V0X36A1
Indoor unit models4TXCB004DS3
Furnace modelS9V2B060U4VSB+RP
Model namePLATINUM 20
Model number4A6V0X36A1

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
34400
Heating Capacity 47F (BTUH)
35400
Heating Capacity 17F (BTUH)
29000
Heating Capacity 5F (BTUH)
22000
Seer2
19.50
HSPF2 Region IV
8.70
EER2 AFull 95F
12.05
COP at 5F
1.78
Refrigerant Type
R-410A

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
No

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Same cooling capacity

Trane

Split-system heat pump

4TWV0X36A1 — Trane AHRI 214639475

AHRI 214639475

Indoor model / pattern
4TXCB004DS3
Furnace model / pattern
S9V2B040U3PSC+RP
Cooling · BTU/h
34,400
SEER2
19.50
HSPF2
8.70

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.
View AHRI
Same cooling capacity

Trane

Split-system heat pump

4TWV8X36A1 — Trane AHRI 211289052

AHRI 211289052

Indoor model / pattern
4PX*CD36BS3+HORIZ-RT
Furnace model / pattern
*UD2C100ACV5
Cooling · BTU/h
34,400
SEER2
18.00
HSPF2
7.80

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 7.80 vs. 8.70
  • Lower heating capacity at 47°F: 32,200 BTU/h.
  • Lower heating capacity at 17°F: 26,800 BTU/h.
  • Lower heating capacity at 5°F: 20,600 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27VNA036A*030* — Carrier AHRI 215669312

AHRI 215669312

Indoor model / pattern
CAA**6024AM*+UI
Furnace model / pattern
58TN*B090C21**20
Cooling · BTU/h
34,400
SEER2
18.50
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 18.50 vs. 19.50
  • Different refrigerant: R-454B (current: R-410A).
View AHRI
Higher SEER2

Carrier

Split-system heat pump

27VNA336A*030* — Carrier AHRI 215932754

AHRI 215932754

Indoor model / pattern
CAA**6121AM*+UI
Furnace model / pattern
59CU5B080C21**20
Cooling · BTU/h
34,400
SEER2
20.00
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 20.00 vs. 19.50
  • Different refrigerant: R-454B (current: R-410A).
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL21KLV-036-230A** — Lennox AHRI 218073755

AHRI 218073755

Indoor model / pattern
CK40[C,U]T-36C-**+TDR
Furnace model / pattern
ML180UH110V60C*
Cooling · BTU/h
34,400
SEER2
18.50
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.50 vs. 8.70
  • Different refrigerant: R-454B (current: R-410A).
  • Lower heating capacity at 47°F: 30,800 BTU/h.
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL18KSLV-036-230A** — Lennox AHRI 218082919

AHRI 218082919

Indoor model / pattern
CK40[C,U]T-36C-**+TDR
Furnace model / pattern
ML193UH090XE36C*
Cooling · BTU/h
34,400
SEER2
18.30
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.50 vs. 8.70
  • Different refrigerant: R-454B (current: R-410A).
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service

Popular cities

Service Areas