ENERGY STAR AHRI details

AC PRO SPHP-M-1042BB

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandAC PRO
Outdoor unit modelSPHP-M-1042BB
Indoor unit modelsAIRH-M-1048E16B
Model nameSPHP-M
Model numberSPHP-M-1042BB

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
41500
Heating Capacity 47F (BTUH)
40500
Heating Capacity 17F (BTUH)
24800
Heating Capacity 5F (BTUH)
20200
Seer2
15.20
HSPF2 Region IV
7.80
EER2 AFull 95F
12.00
COP at 5F
2.30
Refrigerant Type
R-454B

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
No

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Higher SEER2

Trane

Split-system heat pump

5TWX6042A1 — Trane AHRI 218110828

AHRI 218110828

Indoor model / pattern
5TXCD010AS3+TSTAT+P0V0D000M50SD
Cooling · BTU/h
41,500
SEER2
16.00
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 16.00 vs. 15.20
  • Lower heating capacity at 5°F: 18,900 BTU/h.
View AHRI
Higher SEER2

Trane

Split-system heat pump

5TWX5042A1 — Trane AHRI 215687387

AHRI 215687387

Indoor model / pattern
5PX*D010AS3+TSTAT+P0V0D000M50SD
Cooling · BTU/h
41,500
SEER2
16.50
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 16.50 vs. 15.20
  • Lower heating capacity at 5°F: 19,100 BTU/h.
View AHRI
Higher SEER2

Carrier

Split-system heat pump

27SCA542A**30* — Carrier AHRI 214180030

AHRI 214180030

Indoor model / pattern
FT5ANBD60L*
Cooling · BTU/h
41,500
SEER2
15.50
HSPF2
7.80

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 15.50 vs. 15.20
  • Lower heating capacity at 5°F: 19,000 BTU/h.
View AHRI
Higher SEER2

Carrier

Split-system heat pump

27SPA642A**30* — Carrier AHRI 214180031

AHRI 214180031

Indoor model / pattern
FT5ANBD60L*
Cooling · BTU/h
41,500
SEER2
15.50
HSPF2
7.80

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 15.50 vs. 15.20
  • Lower heating capacity at 5°F: 19,000 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.