ENERGY STAR AHRI details

York YH648E2S11

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandYork
Outdoor unit modelYH648E2S11
Indoor unit modelsCTU60D5XGS1+TXV
Furnace modelY92E120D20SMPS1
Model nameLX SERIES
Model numberYH648E2S11

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
46500
Heating Capacity 47F (BTUH)
49500
Heating Capacity 17F (BTUH)
33800
Heating Capacity 5F (BTUH)
27600
Seer2
16.00
HSPF2 Region IV
8.10
EER2 AFull 95F
12.00
COP at 5F
2.26
Refrigerant Type
R-454B

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
No

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Higher SEER2

Trane

Split-system heat pump

4TWV7X48A1 — Trane AHRI 214639745

AHRI 214639745

Indoor model / pattern
4PX*CD60BS3
Furnace model / pattern
S8V2C080M5PDB
Cooling · BTU/h
46,500
SEER2
17.00
HSPF2
8.20

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 17.00 vs. 16.00
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 47°F: 44,500 BTU/h.
View AHRI
Higher SEER2

Trane

Split-system heat pump

4TWV8X48A1 — Trane AHRI 207526274

AHRI 207526274

Indoor model / pattern
4PX*DU60BS3
Furnace model / pattern
*UHMD120ACV5
Cooling · BTU/h
46,500
SEER2
18.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 18.00 vs. 16.00
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 47°F: 43,000 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27TPA848A**30* — Carrier AHRI 215633915

AHRI 215633915

Indoor model / pattern
CSAH*4812AM*
Furnace model / pattern
59TP6C100V21**20
Cooling · BTU/h
46,500
SEER2
16.00
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.00 vs. 8.10
  • Lower heating capacity at 17°F: 31,000 BTU/h.
  • Lower heating capacity at 5°F: 25,200 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

GH8TAN548**AA* — Carrier AHRI 215633917

AHRI 215633917

Indoor model / pattern
CSAH*4812AM*
Furnace model / pattern
59TP6C100V21**20
Cooling · BTU/h
46,500
SEER2
16.00
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.00 vs. 8.10
  • Lower heating capacity at 17°F: 31,000 BTU/h.
  • Lower heating capacity at 5°F: 25,200 BTU/h.
View AHRI
Higher SEER2

Lennox

Split-system heat pump

EL19KPV-048-230A** — Lennox AHRI 217446810

AHRI 217446810

Indoor model / pattern
CK40HT-51/61C-**+TDR
Furnace model / pattern
SL297UH080NV48C*
Cooling · BTU/h
46,500
SEER2
16.50
HSPF2
8.20

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 16.50 vs. 16.00
  • Lower heating capacity at 17°F: 29,400 BTU/h.
View AHRI
Higher SEER2

Lennox

Split-system heat pump

EL21KLV-048-230A** — Lennox AHRI 217121610

AHRI 217121610

Indoor model / pattern
CK40[C,U]T-50/60C-**+TDR
Furnace model / pattern
EL196UH110XE60C*
Cooling · BTU/h
46,500
SEER2
18.50
HSPF2
8.20

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 18.50 vs. 16.00
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service

Popular cities

Service Areas