ENERGY STAR AHRI details

Armstrong Air A7CP21V48P-**A

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandArmstrong Air
Outdoor unit modelA7CP21V48P-**A
Indoor unit models7EH60DX-**+TDR
Furnace modelA98USMV135D20S*
Model nameA7CP21V Series
Model numberA7CP21V48P-**A

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
47000
Heating Capacity 47F (BTUH)
45500
Heating Capacity 17F (BTUH)
39500
Heating Capacity 5F (BTUH)
31400
Seer2
20.50
HSPF2 Region IV
8.50
EER2 AFull 95F
12.60
COP at 5F
1.96
Refrigerant Type
R-454B

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
No

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Same cooling capacity

Trane

Split-system heat pump

4TWV8X48A1 — Trane AHRI 214640027

AHRI 214640027

Indoor model / pattern
4PX*CD60BS3+HORIZ-RT
Furnace model / pattern
S9V2C080U5PSC+RP
Cooling · BTU/h
47,000
SEER2
18.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 18.00 vs. 20.50
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 17°F: 37,000 BTU/h.
  • Lower heating capacity at 5°F: 28,600 BTU/h.
View AHRI
Same cooling capacity

Trane

Split-system heat pump

4TWV0X48A1 — Trane AHRI 207526440

AHRI 207526440

Indoor model / pattern
4PX*DU60BS3
Furnace model / pattern
S9V2D120U5VSA+RP
Cooling · BTU/h
47,000
SEER2
19.50
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 19.50 vs. 20.50
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 47°F: 42,000 BTU/h.
  • Lower heating capacity at 17°F: 36,200 BTU/h.
  • Lower heating capacity at 5°F: 28,200 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27VPA948A*030* — Carrier AHRI 217914758

AHRI 217914758

Indoor model / pattern
CAA**6121AM*
Furnace model / pattern
58SU*B080M21**20
Cooling · BTU/h
47,000
SEER2
17.50
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 17.50 vs. 20.50
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27VNA048A*030* — Carrier AHRI 215676203

AHRI 215676203

Indoor model / pattern
CVAVA4824XMA*+UI
Furnace model / pattern
58TN*B090C21**20
Cooling · BTU/h
47,000
SEER2
19.00
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 19.00 vs. 20.50
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL21KLV-048-230A** — Lennox AHRI 217117077

AHRI 217117077

Indoor model / pattern
CK40HT-60D-**+TDR
Furnace model / pattern
SLP99UH135XV60D*
Cooling · BTU/h
47,000
SEER2
20.50
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL19KPV-048-230A** — Lennox AHRI 217446823

AHRI 217446823

Indoor model / pattern
CK40DT-50/60C-**+TDR
Furnace model / pattern
ML193DF090XE48C*
Cooling · BTU/h
47,000
SEER2
18.00
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.00 vs. 8.50
  • Lower heating capacity at 17°F: 30,200 BTU/h.
  • Lower heating capacity at 5°F: 29,400 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service

Popular cities

Service Areas