Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandLG
Outdoor unit modelKUSXB301A
Indoor unit modelsLKMMA30B1
Furnace modelLNA**080B1
Model nameKUSXB301A
Model numberKUSXB301A

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
27000
Heating Capacity 47F (BTUH)
30000
Heating Capacity 17F (BTUH)
19000
Heating Capacity 5F (BTUH)
25000
Seer2
17.00
HSPF2 Region IV
8.50
EER2 AFull 95F
11.00
COP at 5F
1.80
Refrigerant Type
R-32

Eligibility

Rebates and certifications

Mass Save QPL
Yes
ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
Yes

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Same cooling capacity

Trane

Split-system heat pump

5TWR5030A1 — Trane AHRI 214078357

AHRI 214078357

Indoor model / pattern
5TXCB004AS3+TSTAT
Furnace model / pattern
S8V2B060M4PCB
Cooling · BTU/h
27,000
SEER2
15.20
HSPF2
7.80

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 7.80 vs. 8.50
  • Different refrigerant: R-454B (current: R-32).
  • Lower heating capacity at 47°F: 25,600 BTU/h.
  • Lower heating capacity at 17°F: 17,200 BTU/h.
  • Lower heating capacity at 5°F: 13,300 BTU/h.
View AHRI
Same cooling capacity

Trane

Split-system heat pump

5TWX5030A1 — Trane AHRI 214182131

AHRI 214182131

Indoor model / pattern
5TXCB004AS3+TSTAT
Furnace model / pattern
S8V2B060M4PCB
Cooling · BTU/h
27,000
SEER2
15.20
HSPF2
7.80

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 7.80 vs. 8.50
  • Different refrigerant: R-454B (current: R-32).
  • Lower heating capacity at 47°F: 25,600 BTU/h.
  • Lower heating capacity at 17°F: 17,200 BTU/h.
  • Lower heating capacity at 5°F: 13,300 BTU/h.
View AHRI
Similar cooling capacity

Carrier

Split-system heat pump

25SCA530A**30* — Carrier AHRI 210309871

AHRI 210309871

Indoor model / pattern
CAP**3721AL*
Furnace model / pattern
58S(B,C)*A090E21**20
Cooling · BTU/h
27,800
SEER2
15.20
HSPF2
7.80

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity +3.0%Similar cooling capacity.Lower HSPF2 (Region IV): 7.80 vs. 8.50
  • Different refrigerant: R-410A (current: R-32).
  • Lower heating capacity at 47°F: 28,000 BTU/h.
  • Lower heating capacity at 17°F: 16,900 BTU/h.
  • Lower heating capacity at 5°F: 12,900 BTU/h.
View AHRI
Similar cooling capacity

Carrier

Split-system heat pump

25SPA530A**30* — Carrier AHRI 210309872

AHRI 210309872

Indoor model / pattern
CAP**3721AL*
Furnace model / pattern
58S(B,C)*A090E21**20
Cooling · BTU/h
27,800
SEER2
15.20
HSPF2
7.80

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity +3.0%Similar cooling capacity.Lower HSPF2 (Region IV): 7.80 vs. 8.50
  • Different refrigerant: R-410A (current: R-32).
  • Lower heating capacity at 47°F: 28,000 BTU/h.
  • Lower heating capacity at 17°F: 16,900 BTU/h.
  • Lower heating capacity at 5°F: 12,900 BTU/h.
View AHRI
Similar cooling capacity

Lennox

Split-system heat pump

ML17XP1-030-230A** — Lennox AHRI 210047068

AHRI 210047068

Indoor model / pattern
CHX35-36C-**-*+TDR
Furnace model / pattern
EL196UH090XE48C*
Cooling · BTU/h
28,200
SEER2
15.60
HSPF2
8.30

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity +4.4%Similar cooling capacity.Lower HSPF2 (Region IV): 8.30 vs. 8.50
  • Different refrigerant: R-410A (current: R-32).
  • Lower heating capacity at 47°F: 28,000 BTU/h.
  • Lower heating capacity at 5°F: 14,500 BTU/h.
View AHRI
Similar cooling capacity

Lennox

Split-system heat pump

EL17XP1-030-230A** — Lennox AHRI 210291748

AHRI 210291748

Indoor model / pattern
CHX35-36C-**-*+TDR
Furnace model / pattern
EL196UH090XE48C*
Cooling · BTU/h
28,200
SEER2
15.60
HSPF2
8.30

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity +4.4%Similar cooling capacity.Lower HSPF2 (Region IV): 8.30 vs. 8.50
  • Different refrigerant: R-410A (current: R-32).
  • Lower heating capacity at 47°F: 28,000 BTU/h.
  • Lower heating capacity at 5°F: 14,500 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.