Mass Save AHRI details

Carrier 37MUHAQ30AA3+TIC2025-0016

ENERGY STAR Certified · Mass Save Eligible HP - Split System

Mass Save rebate eligible

Mass Save® rebates for this qualified system

Green Flow Solution can help confirm the equipment match, project eligibility, utility requirements, and rebate paperwork before installation or replacement.

Claim your rebates today
Mass Save Heat Pump Leader logo

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandCarrier
Outdoor unit model37MUHAQ30AA3+TIC2025-0016
Indoor unit modelsCSAH*3612AM*
Furnace model58SP*B070V17**16
Model nameCrossover Heat Pump
Model number37MUHAQ30AA3+TIC2025-0016

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
29600
Heating Capacity 47F (BTUH)
36800
Heating Capacity 17F (BTUH)
21200
Heating Capacity 5F (BTUH)
32600
Seer2
15.20
HSPF2 Region IV
8.50
EER2 AFull 95F
9.80
COP at 5F
1.82
Refrigerant Type
R-454B

Eligibility

Rebates and certifications

Mass Save QPL
Yes
ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
Yes

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Higher SEER2

Trane

Split-system heat pump

5TWX6030A1 — Trane AHRI 218112422

AHRI 218112422

Indoor model / pattern
5PX*C009AS3+TSTAT
Furnace model / pattern
S8X2C080M5PSC
Cooling · BTU/h
29,400
SEER2
15.50
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity −0.7%Similar cooling capacity.Lower HSPF2 (Region IV): 8.10 vs. 8.50
  • Lower heating capacity at 47°F: 25,800 BTU/h.
  • Lower heating capacity at 17°F: 17,200 BTU/h.
  • Lower heating capacity at 5°F: 13,400 BTU/h.
View AHRI
Similar cooling capacity

Trane

Split-system heat pump

5TWR6030A1 — Trane AHRI 218111805

AHRI 218111805

Indoor model / pattern
5PX*D008AS3+TSTAT
Furnace model / pattern
S9X2D120U5PSB
Cooling · BTU/h
29,200
SEER2
15.20
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity −1.4%Similar cooling capacity.Lower HSPF2 (Region IV): 8.10 vs. 8.50
  • Lower heating capacity at 47°F: 26,000 BTU/h.
  • Lower heating capacity at 17°F: 17,200 BTU/h.
  • Lower heating capacity at 5°F: 13,300 BTU/h.
View AHRI
Same outdoor unit

Carrier

Split-system heat pump

37MUHAQ30AA3+TIC2025-0016 — Carrier AHRI 217382958

AHRI 217382958

Indoor model / pattern
CSAH*3612AM*
Furnace model / pattern
58SP*B090V21**20
Cooling · BTU/h
29,600
SEER2
15.20
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySame outdoor unit, different indoor combination.
View AHRI
Same brand

Carrier

Split-system heat pump

27SPA631A**30* — Carrier AHRI 217690339

AHRI 217690339

Indoor model / pattern
CAA**3721AM*
Furnace model / pattern
58SU*B080M21**20
Cooling · BTU/h
29,400
SEER2
15.50
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity −0.7%Similar cooling capacity.Lower HSPF2 (Region IV): 8.00 vs. 8.50
  • Lower heating capacity at 47°F: 30,600 BTU/h.
  • Lower heating capacity at 17°F: 18,100 BTU/h.
  • Lower heating capacity at 5°F: 14,000 BTU/h.
View AHRI
Higher SEER2

Lennox

Split-system heat pump

EL17XP1-030-230A** — Lennox AHRI 213257766

AHRI 213257766

Indoor model / pattern
CRX35-42B-**-*+TDR
Furnace model / pattern
ML296DF070XV48B*
Cooling · BTU/h
29,600
SEER2
15.60
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 15.60 vs. 15.20
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 47°F: 30,000 BTU/h.
  • Lower heating capacity at 17°F: 19,500 BTU/h.
  • Lower heating capacity at 5°F: 15,300 BTU/h.
View AHRI
Higher SEER2

Lennox

Split-system heat pump

ML17XP1-030-230A** — Lennox AHRI 213258003

AHRI 213258003

Indoor model / pattern
CRX35-42B-**-*+TDR
Furnace model / pattern
ML296DF070XV48B*
Cooling · BTU/h
29,600
SEER2
15.60
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 15.60 vs. 15.20
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 47°F: 30,000 BTU/h.
  • Lower heating capacity at 17°F: 19,500 BTU/h.
  • Lower heating capacity at 5°F: 15,300 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service

Popular cities

Service Areas