Mass Save AHRI details

Carrier 37MUHAQ30AA3+TIC2025-0016

ENERGY STAR Certified · Mass Save Eligible HP - Split System

Mass Save rebate eligible

Mass Save® rebates for this qualified system

Green Flow Solution can help confirm the equipment match, project eligibility, utility requirements, and rebate paperwork before installation or replacement.

Claim your rebates today
Mass Save Heat Pump Leader logo

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandCarrier
Outdoor unit model37MUHAQ30AA3+TIC2025-0016
Indoor unit modelsCAA**4221AM*
Furnace model59SP6B080V17**16
Model nameCrossover Heat Pump
Model number37MUHAQ30AA3+TIC2025-0016

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
29000
Heating Capacity 47F (BTUH)
37000
Heating Capacity 17F (BTUH)
21200
Heating Capacity 5F (BTUH)
33000
Seer2
15.50
HSPF2 Region IV
8.50
EER2 AFull 95F
9.50
COP at 5F
1.80
Refrigerant Type
R-454B

Eligibility

Rebates and certifications

Mass Save QPL
Yes
ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
Yes

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Same outdoor unit

Carrier

Split-system heat pump

37MUHAQ30AA3+TIC2025-0016 — Carrier AHRI 217383362

AHRI 217383362

Indoor model / pattern
CAA**4221AM*
Furnace model / pattern
58S(B,C)*B090M21**16
Cooling · BTU/h
29,000
SEER2
15.50
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySame outdoor unit, different indoor combination.
View AHRI
Same brand

Carrier

Split-system heat pump

27SCA531A**30* — Carrier AHRI 217680772

AHRI 217680772

Indoor model / pattern
CAA**3721AM*
Furnace model / pattern
59SU5B100M21**22
Cooling · BTU/h
29,200
SEER2
15.50
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity +0.7%Similar cooling capacity.Lower HSPF2 (Region IV): 8.00 vs. 8.50
  • Lower heating capacity at 47°F: 30,600 BTU/h.
  • Lower heating capacity at 17°F: 18,200 BTU/h.
  • Lower heating capacity at 5°F: 14,000 BTU/h.
View AHRI
Similar cooling capacity

Fujitsu

Split-system heat pump

FOP1530TJAZNA — Fujitsu AHRI 212507645

AHRI 212507645

Indoor model / pattern
FCCN3617SZTA
Furnace model / pattern
FF95SV306017M4S*A
Cooling · BTU/h
28,400
SEER2
15.20
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity −2.1%Similar cooling capacity.Lower HSPF2 (Region IV): 8.10 vs. 8.50
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 47°F: 28,400 BTU/h.
  • Lower heating capacity at 5°F: 16,100 BTU/h.
View AHRI
Similar cooling capacity

Fujitsu

Split-system heat pump

WP15AZ30AJ2N — Fujitsu AHRI 212507749

AHRI 212507749

Indoor model / pattern
FCCN3617SZTA
Furnace model / pattern
FF95SV306017M4S*A
Cooling · BTU/h
28,400
SEER2
15.20
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity −2.1%Similar cooling capacity.Lower HSPF2 (Region IV): 8.10 vs. 8.50
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 47°F: 28,400 BTU/h.
  • Lower heating capacity at 5°F: 16,100 BTU/h.
View AHRI
Higher SEER2

Trane

Split-system heat pump

5TWX5030A1 — Trane AHRI 215686642

AHRI 215686642

Indoor model / pattern
5PX*C007AS3+TSTAT
Furnace model / pattern
S8V2C100M5PCB
Cooling · BTU/h
29,000
SEER2
16.00
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.10 vs. 8.50
  • Lower heating capacity at 47°F: 26,000 BTU/h.
  • Lower heating capacity at 17°F: 17,500 BTU/h.
  • Lower heating capacity at 5°F: 13,600 BTU/h.
View AHRI
Higher SEER2

Trane

Split-system heat pump

5TWR5030A1 — Trane AHRI 215567964

AHRI 215567964

Indoor model / pattern
5PX*C007AS3+TSTAT
Furnace model / pattern
S8V2C100M5PDB
Cooling · BTU/h
29,000
SEER2
16.00
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.00 vs. 8.50
  • Lower heating capacity at 47°F: 26,000 BTU/h.
  • Lower heating capacity at 17°F: 17,500 BTU/h.
  • Lower heating capacity at 5°F: 13,600 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Brands We Service