Mass Save AHRI details

Carrier 37MUHAQ30AA3+TIC2025-0016

ENERGY STAR Certified · Mass Save Eligible HP - Split System

Mass Save rebate eligible

Mass Save® rebates for this qualified system

Green Flow Solution can help confirm the equipment match, project eligibility, utility requirements, and rebate paperwork before installation or replacement.

Claim your rebates today
Mass Save Heat Pump Leader logo

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandCarrier
Outdoor unit model37MUHAQ30AA3+TIC2025-0016
Indoor unit modelsCAA**3617AM*
Furnace model58SP*B090V17**16
Model nameCrossover Heat Pump
Model number37MUHAQ30AA3+TIC2025-0016

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
28600
Heating Capacity 47F (BTUH)
37200
Heating Capacity 17F (BTUH)
21400
Heating Capacity 5F (BTUH)
33200
Seer2
16.00
HSPF2 Region IV
8.50
EER2 AFull 95F
9.80
COP at 5F
1.78
Refrigerant Type
R-454B

Eligibility

Rebates and certifications

Mass Save QPL
Yes
ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
Yes

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Same cooling capacity

Trane

Split-system heat pump

5TWR6030A1 — Trane AHRI 218395222

AHRI 218395222

Indoor model / pattern
5PX*B006AS3+TSTAT
Furnace model / pattern
S9X1B040U3PSB
Cooling · BTU/h
28,600
SEER2
16.00
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.10 vs. 8.50
  • Lower heating capacity at 47°F: 26,000 BTU/h.
  • Lower heating capacity at 17°F: 17,700 BTU/h.
  • Lower heating capacity at 5°F: 13,800 BTU/h.
View AHRI
Same cooling capacity

Trane

Split-system heat pump

5TWR5030A1 — Trane AHRI 215568008

AHRI 215568008

Indoor model / pattern
5PX*CD07AS3+TSTAT
Furnace model / pattern
S9V2C100D5PSC
Cooling · BTU/h
28,600
SEER2
16.00
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.10 vs. 8.50
  • Lower heating capacity at 47°F: 26,000 BTU/h.
  • Lower heating capacity at 17°F: 17,600 BTU/h.
  • Lower heating capacity at 5°F: 13,600 BTU/h.
View AHRI
Same outdoor unit

Carrier

Split-system heat pump

37MUHAQ30AA3+TIC2025-0016 — Carrier AHRI 217383683

AHRI 217383683

Indoor model / pattern
CAA**3617AM*
Furnace model / pattern
58TP*B090V17**16
Cooling · BTU/h
28,600
SEER2
16.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySame outdoor unit, different indoor combination.
View AHRI
Same brand

Carrier

Split-system heat pump

27SCA531A**30* — Carrier AHRI 217680772

AHRI 217680772

Indoor model / pattern
CAA**3721AM*
Furnace model / pattern
59SU5B100M21**22
Cooling · BTU/h
29,200
SEER2
15.50
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity +2.1%Similar cooling capacity.Lower HSPF2 (Region IV): 8.00 vs. 8.50
  • Lower heating capacity at 47°F: 30,600 BTU/h.
  • Lower heating capacity at 17°F: 18,200 BTU/h.
  • Lower heating capacity at 5°F: 14,000 BTU/h.
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL17XP1-030-230A** — Lennox AHRI 213630238

AHRI 213630238

Indoor model / pattern
CHX35-36C-**-*+TDR
Furnace model / pattern
EL297UH090XE48C*
Cooling · BTU/h
28,600
SEER2
15.80
HSPF2
8.30

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.30 vs. 8.50
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 47°F: 28,000 BTU/h.
  • Lower heating capacity at 17°F: 18,400 BTU/h.
  • Lower heating capacity at 5°F: 14,500 BTU/h.
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

ML17XP1-030-230A** — Lennox AHRI 213630280

AHRI 213630280

Indoor model / pattern
CHX35-36C-**-*+TDR
Furnace model / pattern
EL297UH090XE48C*
Cooling · BTU/h
28,600
SEER2
15.80
HSPF2
8.30

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.30 vs. 8.50
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 47°F: 28,000 BTU/h.
  • Lower heating capacity at 17°F: 18,400 BTU/h.
  • Lower heating capacity at 5°F: 14,500 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service

Popular cities

Service Areas