Mass Save AHRI details

Carrier 37MUHAQ30AA3+TIC2025-0016

ENERGY STAR Certified · Mass Save Eligible HP - Split System

Mass Save rebate eligible

Mass Save® rebates for this qualified system

Green Flow Solution can help confirm the equipment match, project eligibility, utility requirements, and rebate paperwork before installation or replacement.

Claim your rebates today
Mass Save Heat Pump Leader logo

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandCarrier
Outdoor unit model37MUHAQ30AA3+TIC2025-0016
Indoor unit modelsCAA**4221AM*
Furnace modelGG96VTAB48060B**
Model nameCrossover Heat Pump
Model number37MUHAQ30AA3+TIC2025-0016

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
29200
Heating Capacity 47F (BTUH)
37000
Heating Capacity 17F (BTUH)
21200
Heating Capacity 5F (BTUH)
33000
Seer2
16.00
HSPF2 Region IV
8.50
EER2 AFull 95F
9.80
COP at 5F
1.80
Refrigerant Type
R-454B

Eligibility

Rebates and certifications

Mass Save QPL
Yes
ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
Yes

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Same cooling capacity

Trane

Split-system heat pump

5TWX6030A1 — Trane AHRI 218112423

AHRI 218112423

Indoor model / pattern
5PX*C009AS3+TSTAT
Furnace model / pattern
S9X1C100U5PSB
Cooling · BTU/h
29,200
SEER2
16.00
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.10 vs. 8.50
  • Lower heating capacity at 47°F: 25,800 BTU/h.
  • Lower heating capacity at 17°F: 17,200 BTU/h.
  • Lower heating capacity at 5°F: 13,300 BTU/h.
View AHRI
Same cooling capacity

Trane

Split-system heat pump

5TWR6030A1 — Trane AHRI 218111767

AHRI 218111767

Indoor model / pattern
5PX*C009AS3+TSTAT
Furnace model / pattern
S9V2C080U5VSB
Cooling · BTU/h
29,200
SEER2
16.00
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.10 vs. 8.50
  • Lower heating capacity at 47°F: 25,800 BTU/h.
  • Lower heating capacity at 17°F: 17,100 BTU/h.
  • Lower heating capacity at 5°F: 13,400 BTU/h.
View AHRI
Same outdoor unit

Carrier

Split-system heat pump

37MUHAQ30AA3+TIC2025-0016 — Carrier AHRI 217383415

AHRI 217383415

Indoor model / pattern
CAA**4221AM*
Furnace model / pattern
59SP6B060V17**16
Cooling · BTU/h
29,200
SEER2
16.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySame outdoor unit, different indoor combination.
View AHRI
Same brand

Carrier

Split-system heat pump

27SCA531A**30* — Carrier AHRI 217680772

AHRI 217680772

Indoor model / pattern
CAA**3721AM*
Furnace model / pattern
59SU5B100M21**22
Cooling · BTU/h
29,200
SEER2
15.50
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.00 vs. 8.50
  • Lower heating capacity at 47°F: 30,600 BTU/h.
  • Lower heating capacity at 17°F: 18,200 BTU/h.
  • Lower heating capacity at 5°F: 14,000 BTU/h.
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

ML17XP1-030-230A** — Lennox AHRI 210047094

AHRI 210047094

Indoor model / pattern
CHX35-36C-**-*+TDR
Furnace model / pattern
ML193UH110XE60C*
Cooling · BTU/h
29,200
SEER2
15.60
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 15.60 vs. 16.00
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 47°F: 28,600 BTU/h.
  • Lower heating capacity at 17°F: 18,800 BTU/h.
  • Lower heating capacity at 5°F: 14,800 BTU/h.
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL17XP1-030-230A** — Lennox AHRI 210291770

AHRI 210291770

Indoor model / pattern
CHX35-36C-**-*+TDR
Furnace model / pattern
ML193UH110XE60C*
Cooling · BTU/h
29,200
SEER2
15.60
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 15.60 vs. 16.00
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 47°F: 28,600 BTU/h.
  • Lower heating capacity at 17°F: 18,800 BTU/h.
  • Lower heating capacity at 5°F: 14,800 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.