ENERGY STAR AHRI details

Heil R5H5S19*K*AAA*

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandHeil
Outdoor unit modelR5H5S19*K*AAA*
Indoor unit modelsFHMA5*18L*A*
Model name15 SEER2 HP
Model numberR5H5S19*K*AAA*

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
18200
Heating Capacity 47F (BTUH)
19000
Heating Capacity 17F (BTUH)
10600
Heating Capacity 5F (BTUH)
8100
Seer2
15.20
HSPF2 Region IV
7.80
EER2 AFull 95F
12.50
COP at 5F
1.90
Refrigerant Type
R-454B

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
No

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Similar cooling capacity

Trane

Split-system heat pump

5TWR6018A1 — Trane AHRI 218105932

AHRI 218105932

Indoor model / pattern
5TEM6B03AV21+TDR+TSTAT
Cooling · BTU/h
18,800
SEER2
15.20
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity +3.3%Similar cooling capacity.
View AHRI
Similar cooling capacity

Trane

Split-system heat pump

5TWX6018A1 — Trane AHRI 218109622

AHRI 218109622

Indoor model / pattern
5TEM6B03AV21+TDR+TSTAT
Cooling · BTU/h
18,800
SEER2
15.20
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity +3.3%Similar cooling capacity.
View AHRI
Higher SEER2

Lennox

Split-system heat pump

ML14KP1-018-230A** — Lennox AHRI 217219630

AHRI 217219630

Indoor model / pattern
CBK47UHET-024-230-**
Cooling · BTU/h
18,000
SEER2
15.50
HSPF2
7.80

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity −1.1%Similar cooling capacity.Higher SEER2: 15.50 vs. 15.20
  • Lower heating capacity at 47°F: 17,700 BTU/h.
View AHRI
Higher SEER2

Lennox

Split-system heat pump

EL16KP1-018-230A** — Lennox AHRI 217219631

AHRI 217219631

Indoor model / pattern
CBK47UHET-024-230-**
Cooling · BTU/h
18,000
SEER2
15.50
HSPF2
7.80

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity −1.1%Similar cooling capacity.Higher SEER2: 15.50 vs. 15.20
  • Lower heating capacity at 47°F: 17,700 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service

Popular cities