Mass Save AHRI details

Panasonic CU-HM55BAHU

ENERGY STAR Certified · Mass Save Eligible HP - Split System

Mass Save rebate eligible

Mass Save® rebates for this qualified system

Green Flow Solution can help confirm the equipment match, project eligibility, utility requirements, and rebate paperwork before installation or replacement.

Claim your rebates today
Mass Save Heat Pump Leader logo

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandPanasonic
Outdoor unit modelCU-HM55BAHU
Indoor unit modelsCS-HM60BAMU3
Furnace modelS9V2C100U5VS***
Model nameCU Series
Model numberCU-HM55BAHU

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
54000
Heating Capacity 47F (BTUH)
56000
Heating Capacity 17F (BTUH)
36000
Heating Capacity 5F (BTUH)
40000
Seer2
17.10
HSPF2 Region IV
8.40
EER2 AFull 95F
10.30
COP at 5F
1.80
Refrigerant Type
R-454B

Eligibility

Rebates and certifications

Mass Save QPL
Yes
ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
Yes

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Higher SEER2

Trane

Split-system heat pump

5TWV8X60A1 — Trane AHRI 215864713

AHRI 215864713

Indoor model / pattern
5TXCC009AS3
Furnace model / pattern
S9V2C080U5PSC+LRP
Cooling · BTU/h
54,000
SEER2
18.10
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 18.10 vs. 17.10
View AHRI
Same cooling capacity

Trane

Split-system heat pump

4TWV7X60A1 — Trane AHRI 213826745

AHRI 213826745

Indoor model / pattern
4PX*CU60BS3
Furnace model / pattern
L8V1C100U5VSB+LRP
Cooling · BTU/h
54,000
SEER2
17.10
HSPF2
8.20

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.20 vs. 8.40
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 47°F: 53,000 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27TPA860A**30* — Carrier AHRI 215625806

AHRI 215625806

Indoor model / pattern
CVAMA6021XMA*
Furnace model / pattern
58SP*B110V21**22
Cooling · BTU/h
54,000
SEER2
16.00
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.10 vs. 8.40
  • Lower heating capacity at 5°F: 30,000 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

GH8TAN560**AA* — Carrier AHRI 215625807

AHRI 215625807

Indoor model / pattern
CVAMA6021XMA*
Furnace model / pattern
58SP*B110V21**22
Cooling · BTU/h
54,000
SEER2
16.00
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.10 vs. 8.40
  • Lower heating capacity at 5°F: 30,000 BTU/h.
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL18KSLV-060-230A** — Lennox AHRI 217450071

AHRI 217450071

Indoor model / pattern
CK40[C,U]T-60D-**+TDR
Furnace model / pattern
SL280UH135V60D*
Cooling · BTU/h
54,000
SEER2
16.75
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 16.75 vs. 17.10
View AHRI
Higher SEER2

Lennox

Split-system heat pump

EL22XPV-060-230A** — Lennox AHRI 211752855

AHRI 211752855

Indoor model / pattern
CX35-50/60C+TDR
Furnace model / pattern
ML296UH110XV60C*
Cooling · BTU/h
54,000
SEER2
18.00
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.00 vs. 8.40
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 5°F: 30,800 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.