Carrier 27VPA936A*030*

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandCarrier
Outdoor unit model27VPA936A*030*
Indoor unit modelsCAA**4321AM*
Furnace model58SU*B080M21**20
Model namePerformance 19 SEER2 VS HP
Model number27VPA936A*030*

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
35800
Heating Capacity 47F (BTUH)
36400
Heating Capacity 17F (BTUH)
36600
Heating Capacity 5F (BTUH)
24600
Seer2
16.00
HSPF2 Region IV
9.00
EER2 AFull 95F
12.00
COP at 5F
2.05
Refrigerant Type
R-454B

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
No

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Higher SEER2

Trane

Split-system heat pump

5TWV0X36A1 — Trane AHRI 218036345

AHRI 218036345

Indoor model / pattern
5PX*CD09AS3
Furnace model / pattern
S9V2B040D3VSB+VCKIT
Cooling · BTU/h
35,800
SEER2
20.00
HSPF2
9.40

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 20.00 vs. 16.00
  • Lower heating capacity at 47°F: 32,400 BTU/h.
  • Lower heating capacity at 17°F: 31,600 BTU/h.
View AHRI
Higher SEER2

Trane

Split-system heat pump

4TWV0X36A1 — Trane AHRI 211289039

AHRI 211289039

Indoor model / pattern
4PX*CU42BS3
Furnace model / pattern
*UD2C100ACV5
Cooling · BTU/h
35,800
SEER2
20.00
HSPF2
8.70

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.70 vs. 9.00
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 47°F: 32,800 BTU/h.
  • Lower heating capacity at 17°F: 27,000 BTU/h.
  • Lower heating capacity at 5°F: 20,400 BTU/h.
View AHRI
Same outdoor unit

Carrier

Split-system heat pump

27VPA936A*030* — Carrier AHRI 217908621

AHRI 217908621

Indoor model / pattern
CAA**4321AM*
Furnace model / pattern
59SU5B100M21**22
Cooling · BTU/h
35,800
SEER2
15.50
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySame outdoor unit, different indoor combination.Lower SEER2: 15.50 vs. 16.00
View AHRI
Same brand

Carrier

Split-system heat pump

27VNA336A*030* — Carrier AHRI 215936874

AHRI 215936874

Indoor model / pattern
CVAVA6121XMA*+UI
Furnace model / pattern
58TN*B070C17**16
Cooling · BTU/h
35,800
SEER2
22.00
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 22.00 vs. 16.00
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL17XP1-036-230A** — Lennox AHRI 213257804

AHRI 213257804

Indoor model / pattern
CRX35-48C-**-*+TDR
Furnace model / pattern
SL280DF080NV60C*
Cooling · BTU/h
35,800
SEER2
16.00
HSPF2
8.60

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.60 vs. 9.00
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 17°F: 23,800 BTU/h.
  • Lower heating capacity at 5°F: 19,000 BTU/h.
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

ML17XP1-036-230A** — Lennox AHRI 213258041

AHRI 213258041

Indoor model / pattern
CRX35-48C-**-*+TDR
Furnace model / pattern
SL280DF080NV60C*
Cooling · BTU/h
35,800
SEER2
16.00
HSPF2
8.60

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.60 vs. 9.00
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 17°F: 23,800 BTU/h.
  • Lower heating capacity at 5°F: 19,000 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service