ENERGY STAR AHRI details

Carrier 27VPA960A*030*

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandCarrier
Outdoor unit model27VPA960A*030*
Indoor unit modelsCAA**6124AM*
Furnace model58SU*B080M21**20
Model namePerformance 19 SEER2 VS HP
Model number27VPA960A*030*

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
56000
Heating Capacity 47F (BTUH)
58000
Heating Capacity 17F (BTUH)
48500
Heating Capacity 5F (BTUH)
40500
Seer2
16.50
HSPF2 Region IV
8.50
EER2 AFull 95F
11.00
COP at 5F
2.05
Refrigerant Type
R-454B

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
No

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Higher SEER2

Trane

Split-system heat pump

5TWV8X60A1 — Trane AHRI 215864765

AHRI 215864765

Indoor model / pattern
5TXCD010AS3
Furnace model / pattern
S9V2C080U5PSC+LRP
Cooling · BTU/h
54,500
SEER2
18.10
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity −2.7%Similar cooling capacity.Higher SEER2: 18.10 vs. 16.50
View AHRI
Higher SEER2

Trane

Split-system heat pump

4TWV7X60A1 — Trane AHRI 213826745

AHRI 213826745

Indoor model / pattern
4PX*CU60BS3
Furnace model / pattern
L8V1C100U5VSB+LRP
Cooling · BTU/h
54,000
SEER2
17.10
HSPF2
8.20

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity −3.6%Similar cooling capacity.Lower HSPF2 (Region IV): 8.20 vs. 8.50
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 47°F: 53,000 BTU/h.
View AHRI
Same outdoor unit

Carrier

Split-system heat pump

27VPA960A*030* — Carrier AHRI 217918290

AHRI 217918290

Indoor model / pattern
CAA**6121AM*
Furnace model / pattern
58SU*B080M21**20
Cooling · BTU/h
56,000
SEER2
16.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySame outdoor unit, different indoor combination.Lower SEER2: 16.00 vs. 16.50
View AHRI
Same brand

Carrier

Split-system heat pump

27VNA060A*030* — Carrier AHRI 215678033

AHRI 215678033

Indoor model / pattern
CSAH*6012AM*+UI
Furnace model / pattern
58CU*A080C21**20
Cooling · BTU/h
56,000
SEER2
17.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 17.00 vs. 16.50
View AHRI
Higher SEER2

Lennox

Split-system heat pump

SL22KLV-060-230A** — Lennox AHRI 216776129

AHRI 216776129

Indoor model / pattern
CK40[C,U]T-60C-**+TDR
Furnace model / pattern
EL297UH090XV60C*
Cooling · BTU/h
56,000
SEER2
18.20
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 18.20 vs. 16.50
  • Lower heating capacity at 47°F: 51,500 BTU/h.
View AHRI
Higher SEER2

Lennox

Split-system heat pump

EL21KLV-060-230A** — Lennox AHRI 217121518

AHRI 217121518

Indoor model / pattern
CK40[C,U]T-60C-**+TDR
Furnace model / pattern
ML196UH110XE60C*
Cooling · BTU/h
56,000
SEER2
19.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 19.00 vs. 16.50
  • Lower heating capacity at 47°F: 53,500 BTU/h.
  • Lower heating capacity at 17°F: 44,000 BTU/h.
  • Lower heating capacity at 5°F: 35,000 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service