Mass Save AHRI details

Carrier 27VPA948A*030*

ENERGY STAR Certified · Mass Save Eligible HP - Split System

Mass Save rebate eligible

Mass Save® rebates for this qualified system

Green Flow Solution can help confirm the equipment match, project eligibility, utility requirements, and rebate paperwork before installation or replacement.

Claim your rebates today
Mass Save Heat Pump Leader logo

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandCarrier
Outdoor unit model27VPA948A*030*
Indoor unit modelsCAA**6121AM*+TDR
Model namePerformance 19 SEER2 VS HP
Model number27VPA948A*030*

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
45000
Heating Capacity 47F (BTUH)
49000
Heating Capacity 17F (BTUH)
40000
Heating Capacity 5F (BTUH)
36800
Seer2
15.50
HSPF2 Region IV
9.00
EER2 AFull 95F
11.00
COP at 5F
2.08
Refrigerant Type
R-454B

Eligibility

Rebates and certifications

Mass Save QPL
Yes
ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
Yes

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Higher SEER2

Trane

Split-system heat pump

5TWV8X48A1 — Trane AHRI 215865067

AHRI 215865067

Indoor model / pattern
5TXCB006AS3+P0V0B000M40SD+LRP
Cooling · BTU/h
45,000
SEER2
18.10
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.50 vs. 9.00
  • Lower heating capacity at 47°F: 46,000 BTU/h.
View AHRI
Higher SEER2

Trane

Split-system heat pump

5TWV0X48A1 — Trane AHRI 216440264

AHRI 216440264

Indoor model / pattern
5PX*CD09AS3+P0V0C000M50SD+LRP
Cooling · BTU/h
45,000
SEER2
20.00
HSPF2
9.40

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 20.00 vs. 15.50
  • Lower heating capacity at 5°F: 32,800 BTU/h.
View AHRI
Same outdoor unit

Carrier

Split-system heat pump

27VPA948A*030* — Carrier AHRI 217954435

AHRI 217954435

Indoor model / pattern
CAA**6124AM*+TDR
Cooling · BTU/h
45,000
SEER2
15.50
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySame outdoor unit, different indoor combination.
View AHRI
Same brand

Carrier

Split-system heat pump

37MURAQ48AA3 — Carrier AHRI 217456320

AHRI 217456320

Indoor model / pattern
45MULAQ60XMX
Cooling · BTU/h
45,000
SEER2
15.20
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 15.20 vs. 15.50
  • Lower heating capacity at 17°F: 33,000 BTU/h.
View AHRI
Higher SEER2

Lennox

Split-system heat pump

EL21KLV-048-230A** — Lennox AHRI 217443371

AHRI 217443371

Indoor model / pattern
CK40HT-51/61C-**+TDR
Cooling · BTU/h
45,000
SEER2
16.00
HSPF2
8.20

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.20 vs. 9.00
  • Lower heating capacity at 47°F: 44,500 BTU/h.
  • Lower heating capacity at 17°F: 37,200 BTU/h.
  • Lower heating capacity at 5°F: 34,000 BTU/h.
View AHRI
Higher SEER2

Lennox

Split-system heat pump

SL22KLV-048-230A** — Lennox AHRI 216776087

AHRI 216776087

Indoor model / pattern
CBK48MVT-048-230-**
Cooling · BTU/h
45,000
SEER2
20.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.50 vs. 9.00
  • Lower heating capacity at 47°F: 46,000 BTU/h.
View AHRI