Mass Save AHRI details

York YH960E2C11

ENERGY STAR Certified · Mass Save Eligible HP - Split System

Mass Save rebate eligible

Mass Save® rebates for this qualified system

Green Flow Solution can help confirm the equipment match, project eligibility, utility requirements, and rebate paperwork before installation or replacement.

Claim your rebates today
Mass Save Heat Pump Leader logo

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandYork
Outdoor unit modelYH960E2C11
Indoor unit modelsCTM60C5CHS1+CC
Furnace modelTPLC100C20MP13
Model nameLX SERIES
Model numberYH960E2C11

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
55000
Heating Capacity 47F (BTUH)
58000
Heating Capacity 17F (BTUH)
47000
Heating Capacity 5F (BTUH)
44000
Seer2
20.00
HSPF2 Region IV
8.50
EER2 AFull 95F
10.00
COP at 5F
2.00
Refrigerant Type
R-454B

Eligibility

Rebates and certifications

Mass Save QPL
Yes
ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
Yes

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Similar cooling capacity

Trane

Split-system heat pump

5TWV8X60A1 — Trane AHRI 215864765

AHRI 215864765

Indoor model / pattern
5TXCD010AS3
Furnace model / pattern
S9V2C080U5PSC+LRP
Cooling · BTU/h
54,500
SEER2
18.10
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity −0.9%Similar cooling capacity.Lower SEER2: 18.10 vs. 20.00
  • Lower heating capacity at 5°F: 40,000 BTU/h.
View AHRI
Similar cooling capacity

Trane

Split-system heat pump

5TWV0X60A1 — Trane AHRI 216440550

AHRI 216440550

Indoor model / pattern
5TXCD010AS3
Furnace model / pattern
L8V1C100U5VSB+LRP
Cooling · BTU/h
54,000
SEER2
19.00
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity −1.8%Similar cooling capacity.Lower SEER2: 19.00 vs. 20.00
  • Lower heating capacity at 47°F: 53,500 BTU/h.
  • Lower heating capacity at 5°F: 38,500 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27VNA060A*030* — Carrier AHRI 215677843

AHRI 215677843

Indoor model / pattern
CAA**6024AM*+UI
Furnace model / pattern
59MN7C100C21**22
Cooling · BTU/h
55,000
SEER2
18.50
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 18.50 vs. 20.00
  • Lower heating capacity at 5°F: 41,500 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27VPA960A*030* — Carrier AHRI 217918251

AHRI 217918251

Indoor model / pattern
CAA**6024AM*
Furnace model / pattern
58SU*B080M21**20
Cooling · BTU/h
55,000
SEER2
16.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 16.00 vs. 20.00
  • Lower heating capacity at 5°F: 40,500 BTU/h.
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

SL22KLV-060-230A** — Lennox AHRI 216776145

AHRI 216776145

Indoor model / pattern
CK40[C,U]T-60D-**+TDR
Furnace model / pattern
SLP99UH135XV60D*
Cooling · BTU/h
55,000
SEER2
19.50
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 19.50 vs. 20.00
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL21KLV-060-230A** — Lennox AHRI 217121488

AHRI 217121488

Indoor model / pattern
CK40[C,U]T-49C-**+TDR
Furnace model / pattern
EL180UH100NE60C*
Cooling · BTU/h
55,000
SEER2
19.50
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 19.50 vs. 20.00
  • Lower heating capacity at 47°F: 54,500 BTU/h.
  • Lower heating capacity at 5°F: 35,800 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service