Mass Save AHRI details

Lennox EL18KSLV-036-230A**

ENERGY STAR Certified · Mass Save Eligible HP - Split System

Mass Save rebate eligible

Mass Save® rebates for this qualified system

Green Flow Solution can help confirm the equipment match, project eligibility, utility requirements, and rebate paperwork before installation or replacement.

Claim your rebates today
Mass Save Heat Pump Leader logo

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandLennox
Outdoor unit modelEL18KSLV-036-230A**
Indoor unit modelsCK40[C,U]T-36C-**+TDR
Furnace modelML180UH110V60C*
Model nameEL18KSLV Series
Model numberEL18KSLV-036-230A**

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
35200
Heating Capacity 47F (BTUH)
35600
Heating Capacity 17F (BTUH)
29400
Heating Capacity 5F (BTUH)
28200
Seer2
18.80
HSPF2 Region IV
8.50
EER2 AFull 95F
11.00
COP at 5F
1.90
Refrigerant Type
R-454B

Eligibility

Rebates and certifications

Mass Save QPL
Yes
ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
Yes

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Same cooling capacity

Trane

Split-system heat pump

4TWV8X36A1 — Trane AHRI 214640007

AHRI 214640007

Indoor model / pattern
4TXCB006DS3
Furnace model / pattern
S9V2B040U3PSC+RP
Cooling · BTU/h
35,200
SEER2
18.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 18.00 vs. 18.80
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 47°F: 32,400 BTU/h.
  • Lower heating capacity at 17°F: 26,600 BTU/h.
  • Lower heating capacity at 5°F: 21,000 BTU/h.
View AHRI
Higher SEER2

Trane

Split-system heat pump

4TWV0X36A1 — Trane AHRI 210691825

AHRI 210691825

Indoor model / pattern
4PX*CU42BS3
Furnace model / pattern
S8V2C080M5PCA
Cooling · BTU/h
35,200
SEER2
19.50
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 19.50 vs. 18.80
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 47°F: 32,600 BTU/h.
  • Lower heating capacity at 17°F: 26,800 BTU/h.
  • Lower heating capacity at 5°F: 20,400 BTU/h.
View AHRI
Higher SEER2

Carrier

Split-system heat pump

27VNA336A*030* — Carrier AHRI 215942390

AHRI 215942390

Indoor model / pattern
CVAMA4921XMA*+UI
Furnace model / pattern
59TN6C060C17**14
Cooling · BTU/h
35,200
SEER2
21.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 21.00 vs. 18.80
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

37MUHAQ36AA3+KSAIC0701230 — Carrier AHRI 218516482

AHRI 218516482

Indoor model / pattern
CAA**4821AM*
Furnace model / pattern
59SC2E080M21**20
Cooling · BTU/h
35,200
SEER2
16.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 16.00 vs. 18.80
  • Lower heating capacity at 17°F: 24,800 BTU/h.
View AHRI
Same outdoor unit

Lennox

Split-system heat pump

EL18KSLV-036-230A** — Lennox AHRI 218082926

AHRI 218082926

Indoor model / pattern
CK40[C,U]T-36C-**+TDR
Furnace model / pattern
SL280UH090V60C*
Cooling · BTU/h
35,200
SEER2
18.40
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySame outdoor unit, different indoor combination.Lower SEER2: 18.40 vs. 18.80
View AHRI
Same brand

Lennox

Split-system heat pump

SL22KLV-036-230A** — Lennox AHRI 216776075

AHRI 216776075

Indoor model / pattern
CK40[C,U]T-49C-**+TDR
Furnace model / pattern
SL297UH080NV60C*
Cooling · BTU/h
35,200
SEER2
18.50
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 18.50 vs. 18.80
  • Lower heating capacity at 47°F: 31,400 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.