ENERGY STAR AHRI details

Kenmore XH936E2C11

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandKenmore
Outdoor unit modelXH936E2C11
Indoor unit modelsCTF36C5ADS1+CC
Furnace modelZ8VT100C20SMPC1
Model nameLX SERIES
Model numberXH936E2C11

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
35400
Heating Capacity 47F (BTUH)
35000
Heating Capacity 17F (BTUH)
30400
Heating Capacity 5F (BTUH)
32400
Seer2
18.00
HSPF2 Region IV
9.50
EER2 AFull 95F
11.00
COP at 5F
2.00
Refrigerant Type
R-454B

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
Yes

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Higher SEER2

Trane

Split-system heat pump

5TWV0X36A1 — Trane AHRI 216453113

AHRI 216453113

Indoor model / pattern
5PX*DD10AS3
Furnace model / pattern
S8V2D120M5PDB
Cooling · BTU/h
35,400
SEER2
20.40
HSPF2
9.70

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 20.40 vs. 18.00
  • Lower heating capacity at 47°F: 32,200 BTU/h.
  • Lower heating capacity at 5°F: 24,600 BTU/h.
View AHRI
Same cooling capacity

Trane

Split-system heat pump

4TWV8X36A1 — Trane AHRI 214639993

AHRI 214639993

Indoor model / pattern
4PX*CU42BS3
Furnace model / pattern
S9V2C080U5PSC+RP
Cooling · BTU/h
35,400
SEER2
18.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.50 vs. 9.50
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 47°F: 32,800 BTU/h.
  • Lower heating capacity at 17°F: 26,600 BTU/h.
  • Lower heating capacity at 5°F: 20,400 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

37MUHAQ36AA3+KSAIC0701230 — Carrier AHRI 218516485

AHRI 218516485

Indoor model / pattern
CAA**4821AM*
Furnace model / pattern
59SC2E100M21**20
Cooling · BTU/h
35,400
SEER2
16.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.50 vs. 9.50
  • Lower heating capacity at 17°F: 24,800 BTU/h.
  • Lower heating capacity at 5°F: 30,000 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27VPA936A*030* — Carrier AHRI 217907564

AHRI 217907564

Indoor model / pattern
CVAMA4321XMA*
Furnace model / pattern
58SU*B080M21**20
Cooling · BTU/h
35,400
SEER2
16.50
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.50 vs. 9.50
  • Lower heating capacity at 5°F: 25,000 BTU/h.
View AHRI
Higher SEER2

Lennox

Split-system heat pump

SL22KLV-036-230A** — Lennox AHRI 216776069

AHRI 216776069

Indoor model / pattern
CK40[C,U]T-49C-**+TDR
Furnace model / pattern
SL280UH090V60C*
Cooling · BTU/h
35,400
SEER2
19.00
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 9.00 vs. 9.50
  • Lower heating capacity at 47°F: 31,200 BTU/h.
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL18KSLV-036-230A** — Lennox AHRI 217189887

AHRI 217189887

Indoor model / pattern
CK40DT-42B-**+TDR
Furnace model / pattern
EL280DF090E48B*
Cooling · BTU/h
35,400
SEER2
17.30
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.50 vs. 9.50
  • Lower heating capacity at 17°F: 28,600 BTU/h.
  • Lower heating capacity at 5°F: 28,200 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service

Popular cities

Service Areas