Mass Save AHRI details

Tempstar B5H0V60*K*AAA*

ENERGY STAR Certified · Mass Save Eligible HP - Split System

Mass Save rebate eligible

Mass Save® rebates for this qualified system

Green Flow Solution can help confirm the equipment match, project eligibility, utility requirements, and rebate paperwork before installation or replacement.

Claim your rebates today
Mass Save Heat Pump Leader logo

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandTempstar
Outdoor unit modelB5H0V60*K*AAA*
Indoor unit modelsEVM5X60M21A*+WALLCON
Furnace model*97CMN0602120B*
Model nameSmartSense 20 VS HP
Model numberB5H0V60*K*AAA*

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
55500
Heating Capacity 47F (BTUH)
64500
Heating Capacity 17F (BTUH)
57000
Heating Capacity 5F (BTUH)
46000
Seer2
17.50
HSPF2 Region IV
8.50
EER2 AFull 95F
8.50
COP at 5F
1.94
Refrigerant Type
R-454B

Eligibility

Rebates and certifications

Mass Save QPL
Yes
ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
Yes

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Higher SEER2

Trane

Split-system heat pump

5TWV8X60A1 — Trane AHRI 215864765

AHRI 215864765

Indoor model / pattern
5TXCD010AS3
Furnace model / pattern
S9V2C080U5PSC+LRP
Cooling · BTU/h
54,500
SEER2
18.10
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity −1.8%Similar cooling capacity.Higher SEER2: 18.10 vs. 17.50
  • Lower heating capacity at 47°F: 55,500 BTU/h.
  • Lower heating capacity at 17°F: 49,000 BTU/h.
  • Lower heating capacity at 5°F: 40,000 BTU/h.
View AHRI
Similar cooling capacity

Trane

Split-system heat pump

4TWV7X60A1 — Trane AHRI 213826743

AHRI 213826743

Indoor model / pattern
4PX*CU60BS3
Furnace model / pattern
S9V2C080U5PSB+LRP
Cooling · BTU/h
54,000
SEER2
17.10
HSPF2
8.20

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity −2.7%Similar cooling capacity.Lower HSPF2 (Region IV): 8.20 vs. 8.50
  • Different refrigerant: R-410A (current: R-454B).
  • Lower heating capacity at 47°F: 53,500 BTU/h.
  • Lower heating capacity at 17°F: 50,000 BTU/h.
  • Lower heating capacity at 5°F: 39,500 BTU/h.
View AHRI
Higher SEER2

Carrier

Split-system heat pump

27VNA360A*030* — Carrier AHRI 215931524

AHRI 215931524

Indoor model / pattern
CAA**6024AM*+UI
Furnace model / pattern
58CU*A100C21**20
Cooling · BTU/h
55,500
SEER2
18.50
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 18.50 vs. 17.50
  • Lower heating capacity at 47°F: 60,500 BTU/h.
  • Lower heating capacity at 17°F: 48,000 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27VPA960A*030* — Carrier AHRI 217908355

AHRI 217908355

Indoor model / pattern
CVAVA6121XMA*
Furnace model / pattern
59MN7C100C21**22
Cooling · BTU/h
55,500
SEER2
16.00
HSPF2
8.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.00 vs. 8.50
  • Lower heating capacity at 17°F: 50,500 BTU/h.
  • Lower heating capacity at 5°F: 40,500 BTU/h.
View AHRI
Higher SEER2

Lennox

Split-system heat pump

SL22KLV-060-230A** — Lennox AHRI 216776138

AHRI 216776138

Indoor model / pattern
CK40[C,U]T-49C-**+TDR
Furnace model / pattern
SLP99UH090XV60C*
Cooling · BTU/h
55,500
SEER2
19.50
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 19.50 vs. 17.50
  • Lower heating capacity at 47°F: 51,000 BTU/h.
  • Lower heating capacity at 5°F: 41,500 BTU/h.
View AHRI
Higher SEER2

Lennox

Split-system heat pump

EL21KLV-060-230A** — Lennox AHRI 217121496

AHRI 217121496

Indoor model / pattern
CK40[C,U]T-49C-**+TDR
Furnace model / pattern
ML196UH110XE60C*
Cooling · BTU/h
55,500
SEER2
19.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 19.00 vs. 17.50
  • Lower heating capacity at 47°F: 54,500 BTU/h.
  • Lower heating capacity at 17°F: 46,000 BTU/h.
  • Lower heating capacity at 5°F: 35,800 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service

Popular cities

Service Areas