ENERGY STAR AHRI details

Luxaire XH630E2S11

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandLuxaire
Outdoor unit modelXH630E2S11
Indoor unit modelsCTF36B5ADS1
Furnace modelZ8ES080B12SMPS1
Model nameLX SERIES
Model numberXH630E2S11

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
30200
Heating Capacity 47F (BTUH)
29200
Heating Capacity 17F (BTUH)
19200
Heating Capacity 5F (BTUH)
15400
Seer2
17.00
HSPF2 Region IV
8.10
EER2 AFull 95F
12.50
COP at 5F
2.34
Refrigerant Type
R-454B

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
No

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Similar cooling capacity

Trane

Split-system heat pump

5TWX6030A1 — Trane AHRI 218112449

AHRI 218112449

Indoor model / pattern
5PX*D010AS3+TSTAT
Furnace model / pattern
S9X2D120U5PSB
Cooling · BTU/h
29,400
SEER2
16.00
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity −2.6%Similar cooling capacity.Lower SEER2: 16.00 vs. 17.00
  • Lower heating capacity at 47°F: 25,800 BTU/h.
  • Lower heating capacity at 17°F: 17,100 BTU/h.
  • Lower heating capacity at 5°F: 13,300 BTU/h.
View AHRI
Similar cooling capacity

Trane

Split-system heat pump

5TWR6030A1 — Trane AHRI 218111767

AHRI 218111767

Indoor model / pattern
5PX*C009AS3+TSTAT
Furnace model / pattern
S9V2C080U5VSB
Cooling · BTU/h
29,200
SEER2
16.00
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity −3.3%Similar cooling capacity.Lower SEER2: 16.00 vs. 17.00
  • Lower heating capacity at 47°F: 25,800 BTU/h.
  • Lower heating capacity at 17°F: 17,100 BTU/h.
  • Lower heating capacity at 5°F: 13,400 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27SCA530A**30* — Carrier AHRI 214136564

AHRI 214136564

Indoor model / pattern
CVAVA4224XMA*
Furnace model / pattern
58S(B,C)*B110M24**20
Cooling · BTU/h
30,200
SEER2
15.20
HSPF2
7.80

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 7.80 vs. 8.10
  • Lower heating capacity at 17°F: 17,400 BTU/h.
  • Lower heating capacity at 5°F: 13,500 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27SPA630A**30* — Carrier AHRI 214136565

AHRI 214136565

Indoor model / pattern
CVAVA4224XMA*
Furnace model / pattern
58S(B,C)*B110M24**20
Cooling · BTU/h
30,200
SEER2
15.20
HSPF2
7.80

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 7.80 vs. 8.10
  • Lower heating capacity at 17°F: 17,400 BTU/h.
  • Lower heating capacity at 5°F: 13,500 BTU/h.
View AHRI
Similar cooling capacity

Lennox

Split-system heat pump

ML17XP1-030-230A** — Lennox AHRI 210047118

AHRI 210047118

Indoor model / pattern
CHX35-36C-**-*+TDR
Furnace model / pattern
SLP99UH110XV60C*
Cooling · BTU/h
30,000
SEER2
15.20
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity −0.7%Similar cooling capacity.Lower SEER2: 15.20 vs. 17.00
  • Different refrigerant: R-410A (current: R-454B).
View AHRI
Similar cooling capacity

Lennox

Split-system heat pump

EL17XP1-030-230A** — Lennox AHRI 210291791

AHRI 210291791

Indoor model / pattern
CHX35-36C-**-*+TDR
Furnace model / pattern
SLP99UH110XV60C*
Cooling · BTU/h
30,000
SEER2
15.20
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity −0.7%Similar cooling capacity.Lower SEER2: 15.20 vs. 17.00
  • Different refrigerant: R-410A (current: R-454B).
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service