Mass Save AHRI details

VillaTherm VHPSD-UCHA-36HDCSN4

ENERGY STAR Certified · Mass Save Eligible HP - Split System

Mass Save rebate eligible

Mass Save® rebates for this qualified system

Green Flow Solution can help confirm the equipment match, project eligibility, utility requirements, and rebate paperwork before installation or replacement.

Claim your rebates today
Mass Save Heat Pump Leader logo

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandVillaTherm
Outdoor unit modelVHPSD-UCHA-36HDCSN4
Indoor unit modelsVAH-UCHA-36HDC-A
Model nameSIDE-DISCHARGE
Model numberVHPSD-UCHA-36HDCSN4

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
34200
Heating Capacity 47F (BTUH)
34200
Heating Capacity 17F (BTUH)
28600
Heating Capacity 5F (BTUH)
26000
Seer2
18.00
HSPF2 Region IV
9.00
EER2 AFull 95F
11.00
COP at 5F
2.10
Refrigerant Type
R-454B

Eligibility

Rebates and certifications

Mass Save QPL
Yes
ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
Yes

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Same cooling capacity

Trane

Split-system heat pump

5TWR7036A1 — Trane AHRI 216766220

AHRI 216766220

Indoor model / pattern
5PX*CD07AS3+P0V0C000M50SD
Cooling · BTU/h
34,200
SEER2
17.10
HSPF2
8.70

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.70 vs. 9.00
  • Lower heating capacity at 17°F: 21,600 BTU/h.
  • Lower heating capacity at 5°F: 24,400 BTU/h.
View AHRI
Same cooling capacity

Trane

Split-system heat pump

5TWX7036A1 — Trane AHRI 216766990

AHRI 216766990

Indoor model / pattern
5PX*CD07AS3+P0V0C000M50SD
Cooling · BTU/h
34,200
SEER2
17.10
HSPF2
8.70

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.70 vs. 9.00
  • Lower heating capacity at 17°F: 21,600 BTU/h.
  • Lower heating capacity at 5°F: 24,400 BTU/h.
View AHRI
Similar cooling capacity

Carrier

Split-system heat pump

27VPA936A*030* — Carrier AHRI 218008849

AHRI 218008849

Indoor model / pattern
FT5AN(B,X)C48L*
Cooling · BTU/h
34,400
SEER2
17.00
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity +0.6%Similar cooling capacity.Lower SEER2: 17.00 vs. 18.00
  • Lower heating capacity at 17°F: 24,800 BTU/h.
View AHRI
Similar cooling capacity

Carrier

Split-system heat pump

27TPA836A**30* — Carrier AHRI 216464270

AHRI 216464270

Indoor model / pattern
F55AA*B36L*
Cooling · BTU/h
34,400
SEER2
15.20
HSPF2
8.10

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity +0.6%Similar cooling capacity.Lower HSPF2 (Region IV): 8.10 vs. 9.00
  • Lower heating capacity at 17°F: 23,200 BTU/h.
  • Lower heating capacity at 5°F: 18,800 BTU/h.
View AHRI
Higher SEER2

Lennox

Split-system heat pump

EL21KLV-036-230A** — Lennox AHRI 217121562

AHRI 217121562

Indoor model / pattern
CBK47UHET-036-230-**
Cooling · BTU/h
34,000
SEER2
19.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity −0.6%Similar cooling capacity.Lower HSPF2 (Region IV): 8.50 vs. 9.00
View AHRI
Similar cooling capacity

Lennox

Split-system heat pump

EL18KSLV-036-230A** — Lennox AHRI 216581393

AHRI 216581393

Indoor model / pattern
CK40[C,U]T-36B-**+TDR
Cooling · BTU/h
34,000
SEER2
15.20
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Cooling capacity −0.6%Similar cooling capacity.Lower HSPF2 (Region IV): 8.50 vs. 9.00
  • Lower heating capacity at 17°F: 27,000 BTU/h.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service

Popular cities

Service Areas