ENERGY STAR AHRI details

Kenmore HH836E2S11*

ENERGY STAR Certified HP - Split System

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandKenmore
Outdoor unit modelHH836E2S11*
Indoor unit modelsCTM36C5ADS2
Furnace modelZ9ES100C16SMPS1*
Model nameLX SERIES
Model numberHH836E2S11*

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
34400
Heating Capacity 47F (BTUH)
32600
Heating Capacity 17F (BTUH)
29200
Heating Capacity 5F (BTUH)
26800
Seer2
17.00
HSPF2 Region IV
8.50
EER2 AFull 95F
11.00
COP at 5F
2.00
Refrigerant Type
R-454B

Eligibility

Rebates and certifications

ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
No

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Same cooling capacity

Trane

Split-system heat pump

5TWR7036A1 — Trane AHRI 216769928

AHRI 216769928

Indoor model / pattern
5PX*CD09AS3
Furnace model / pattern
S8X1C100M5PSC
Cooling · BTU/h
34,400
SEER2
17.00
HSPF2
8.70

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.
  • Lower heating capacity at 17°F: 21,400 BTU/h.
  • Lower heating capacity at 5°F: 24,200 BTU/h.
View AHRI
Higher SEER2

Trane

Split-system heat pump

5TWX7036A1 — Trane AHRI 216766974

AHRI 216766974

Indoor model / pattern
5PX*C009AS3
Furnace model / pattern
S9X1C080U5PSB
Cooling · BTU/h
34,400
SEER2
17.10
HSPF2
8.70

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 17.10 vs. 17.00
  • Lower heating capacity at 17°F: 21,400 BTU/h.
  • Lower heating capacity at 5°F: 24,200 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27VNA036A*030* — Carrier AHRI 215670416

AHRI 215670416

Indoor model / pattern
CSAH*6012AM*+UI
Furnace model / pattern
58TN*B070C17**16
Cooling · BTU/h
34,400
SEER2
17.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.
  • Lower heating capacity at 5°F: 25,000 BTU/h.
View AHRI
Higher SEER2

Carrier

Split-system heat pump

27VNA336A*030* — Carrier AHRI 215932754

AHRI 215932754

Indoor model / pattern
CAA**6121AM*+UI
Furnace model / pattern
59CU5B080C21**20
Cooling · BTU/h
34,400
SEER2
20.00
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Higher SEER2: 20.00 vs. 17.00
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL18KSLV-036-230A** — Lennox AHRI 217449856

AHRI 217449856

Indoor model / pattern
CK40[C,U]T-36B-**+TDR
Furnace model / pattern
EL196UH030XE36B*
Cooling · BTU/h
34,400
SEER2
16.95
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower SEER2: 16.95 vs. 17.00
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

SL22KLV-036-230A** — Lennox AHRI 217476502

AHRI 217476502

Indoor model / pattern
CK40HT-60D-**+TDR
Furnace model / pattern
SLP99UH090XV60C*
Cooling · BTU/h
34,400
SEER2
17.00
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.