Technical Specifications

Product Specs

  • AHRI unit role: Indoor
  • AHRI model/pattern: EVD5X42M21A*+WALLCON
  • AHRI records represented: 65
  • AHRI equipment type: Central HP
  • AHRI tonnage: 1.9333333333333333
  • AHRI refrigerant: R-454B
  • Verified catalog model: EVD5X42M21A*+WALLCON
  • Verified product family: EVD5X cased V evaporator coil
  • Verified catalog brand: Kenmore
  • Verified ENERGY STAR dataset: ENERGY STAR Certified Heat Pumps
  • ENERGY STAR partner: Carrier Corporation
  • ENERGY STAR outdoor brand: Kenmore
  • ENERGY STAR series: Deluxe 23 VS Heat Pump
  • ENERGY STAR outdoor model: B5H3V24*K*AAA*
  • ENERGY STAR indoor model: EVD5X42M21A*+WALLCON
  • ENERGY STAR furnace model: *80CSU0401712B*
  • Matched-system SEER2: 22.00
  • Matched-system EER2: 13.50
  • Matched-system HSPF2: 9.50
  • Matched-system cooling capacity: 23,200 BTU/h
  • Matched-system heating capacity at 47F: 27,400 BTU/h
  • Matched-system heating capacity at 17F: 25,600 BTU/h
  • Compressor staging: Continuously variable
  • Refrigerant: R-454B (GWP:470 | Lower GWP)
  • ENERGY STAR certified date: 2026-05-12
  • ENERGY STAR source dataset: https://data.energystar.gov/d/83eb-xbyy
  • Carrier-family public product page: https://www.airquestcomfort.com/en/us/products/evaporator-coils/evd5x
  • Verified Carrier-family model family: EVD5X
  • AHRI indoor model/pattern: EVD5X42M21A*+WALLCON
  • Nominal capacity: 3.5 ton
  • Nominal cooling capacity: 42,000 BTU nominal cooling capacity
  • Cabinet width: 21 in.
  • Configuration: cased V coil with Power-V evaporator coil design
  • Application: matched indoor evaporator coil for air conditioner or heat pump systems

Useful troubleshooting details

  • Confirm the installed model and serial number, matched indoor or outdoor equipment, voltage, refrigerant, controls, and AHRI certificate before service or replacement planning.
  • Use the linked AHRI certificates to verify matched-system combinations, rebate conversations, and equipment eligibility before quoting replacement work.
  • Collect photos of the nameplate, equipment access, recent fault history, and comfort symptoms before dispatch or proposal planning.

Certification match

AHRI certificates

View All
Eligible Central HP <5.4 tons

AHRI 218409150

AHRI 218409150 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit B5H3V24*K*AAA* and indoor unit EVD5X42M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 218409158

AHRI 218409158 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit B5H3V24*K*AAA* and indoor unit EVD5X42M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 218409166

AHRI 218409166 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit B5H3V24*K*AAA* and indoor unit EVD5X42M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 218409174

AHRI 218409174 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit B5H3V24*K*AAA* and indoor unit EVD5X42M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 218409182

AHRI 218409182 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit B5H3V24*K*AAA* and indoor unit EVD5X42M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 218409190

AHRI 218409190 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit B5H3V24*K*AAA* and indoor unit EVD5X42M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 218409198

AHRI 218409198 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit B5H3V24*K*AAA* and indoor unit EVD5X42M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 218409206

AHRI 218409206 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit B5H3V24*K*AAA* and indoor unit EVD5X42M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 218409214

AHRI 218409214 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit B5H3V24*K*AAA* and indoor unit EVD5X42M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 218409222

AHRI 218409222 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit B5H3V24*K*AAA* and indoor unit EVD5X42M21A*+WALLCON.

Loading more

Service planning

How GreenFlow handles EVD5X42M21A* requests

1

Identify the equipment

Confirm the model or series name, serial number if available, photos, and whether the unit is roof, exterior, basement, or mechanical-room equipment.

2

Describe the service issue

Share no heat, no cooling, weak airflow, error codes, alarms, leaks, noise, control problems, or comfort complaints.

3

Review access and history

Include access notes, tenant or business-hour constraints, filter status, recent repairs, and maintenance records when available.

4

Plan the next step

GreenFlow can route the request for diagnostics, repair planning, maintenance, replacement scope, or related system upgrades.

Our Services

Showing services from our catalog

Brands We Service

Popular cities

Service Areas

Our Happy Customers