Gas furnace

Back to Kenmore products

Kenmore Gas furnace *97CMN0602120B*

Kenmore Kenmore AHRI Furnace - Ion 98 Variable-Speed Modulating Gas Furnace Gas furnace Repair, maintenance, and replacement planning
Kenmore *97CMN0602120B* product image

Technical Specifications

Product Specs

  • AHRI unit role: Furnace
  • AHRI model/pattern: *97CMN0602120B*
  • AHRI records represented: 140
  • AHRI equipment type: Central HP
  • AHRI tonnage: 2
  • AHRI refrigerant: R-454B
  • Verified catalog model: *97CMN0602120B*
  • Verified product family: Ion 98 Variable-Speed Modulating Gas Furnace
  • Verified catalog brand: Kenmore
  • Verified ENERGY STAR dataset: ENERGY STAR Certified Heat Pumps
  • ENERGY STAR partner: Carrier Corporation
  • ENERGY STAR outdoor brand: Kenmore
  • ENERGY STAR series: Deluxe 20 VS Heat Pump
  • ENERGY STAR outdoor model: (C,H,T)5H0V24*K*AAA*
  • ENERGY STAR indoor model: EA*5X37M21A*+WALLCON
  • ENERGY STAR furnace model: *97CMN0602120B*
  • Matched-system SEER2: 17.00
  • Matched-system EER2: 10.50
  • Matched-system HSPF2: 9.00
  • Matched-system cooling capacity: 24,000 BTU/h
  • Matched-system heating capacity at 47F: 23,400 BTU/h
  • Matched-system heating capacity at 17F: 19,700 BTU/h
  • Compressor staging: Continuously variable
  • Refrigerant: R-454B (GWP:470 | Lower GWP)
  • ENERGY STAR certified date: 2025-02-17
  • ENERGY STAR source dataset: https://data.energystar.gov/d/83eb-xbyy
  • Carrier-family public product page: https://www.airquestcomfort.com/en/us/products/gas-furnaces/ion-98-variable-speed-modulating-gas-furnace
  • Verified Carrier-family model family: F97CMN
  • AHRI furnace model/pattern: *97CMN0602120B*
  • Nominal input: 60,000 BTU/h input
  • AFUE family: 98%
  • Heating stages: modulating
  • Blower: variable-speed
  • NOx classification: standard
  • Cabinet width code: 21
  • Application: matched gas furnace for split-system air conditioner or heat pump combinations

Useful troubleshooting details

  • Confirm the installed model and serial number, matched indoor or outdoor equipment, voltage, refrigerant, controls, and AHRI certificate before service or replacement planning.
  • Use the linked AHRI certificates to verify matched-system combinations, rebate conversations, and equipment eligibility before quoting replacement work.
  • Collect photos of the nameplate, equipment access, recent fault history, and comfort symptoms before dispatch or proposal planning.

Certification match

AHRI certificates

View All
Eligible Central HP <5.4 tons

AHRI 215667898

AHRI 215667898 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V24*K*AAA* and indoor unit EA*5X37M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215668738

AHRI 215668738 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V36*K*AAA* and indoor unit EA*5X37M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215669230

AHRI 215669230 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V36*K*AAA* and indoor unit EA*5X48M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215669370

AHRI 215669370 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V36*K*AAA* and indoor unit EA*5X60M24A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215669550

AHRI 215669550 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V36*K*AAA* and indoor unit EA*5X61M21A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215669690

AHRI 215669690 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V36*K*AAA* and indoor unit EA*5X61M24A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215669868

AHRI 215669868 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V36*K*AAA* and indoor unit ESH5X36M12A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215670284

AHRI 215670284 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V36*K*AAA* and indoor unit ESH5X48M12A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215670514

AHRI 215670514 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V36*K*AAA* and indoor unit ESH5X60M12A*+WALLCON.

Eligible Central HP <5.4 tons

AHRI 215674102

AHRI 215674102 identifies a Mass Save qualified Central HP <5.4 tons from KENMORE with outdoor unit (C,H,T)5H0V48*K*AAA* and indoor unit EA*5X48M21A*+WALLCON.

Loading more

Service planning

How GreenFlow handles *97CMN0602120B* requests

1

Identify the equipment

Confirm the model or series name, serial number if available, photos, and whether the unit is roof, exterior, basement, or mechanical-room equipment.

2

Describe the service issue

Share no heat, no cooling, weak airflow, error codes, alarms, leaks, noise, control problems, or comfort complaints.

3

Review access and history

Include access notes, tenant or business-hour constraints, filter status, recent repairs, and maintenance records when available.

4

Plan the next step

GreenFlow can route the request for diagnostics, repair planning, maintenance, replacement scope, or related system upgrades.

Our Services

Showing services from our catalog

Brands We Service

Popular cities

Service Areas

Our Happy Customers