Mass Save AHRI details

Ruud UP19AY24AJVC

ENERGY STAR Certified · Mass Save Eligible HP - Split System

Mass Save rebate eligible

Mass Save® rebates for this qualified system

Green Flow Solution can help confirm the equipment match, project eligibility, utility requirements, and rebate paperwork before installation or replacement.

Claim your rebates today
Mass Save Heat Pump Leader logo

Brand and components

Indoor, outdoor, and system model details

Outdoor unit brandRuud
Outdoor unit modelUP19AY24AJVC
Indoor unit modelsRCFY2421HEAAM
Furnace modelR921V0703A17M4
Model nameUltra
Model numberUP19AY24AJVC

Performance specs

Capacity and efficiency

Cooling Capacity (BTUH)
22800
Heating Capacity 47F (BTUH)
22800
Heating Capacity 17F (BTUH)
21200
Heating Capacity 5F (BTUH)
18600
Seer2
20.00
HSPF2 Region IV
10.00
EER2 AFull 95F
12.00
COP at 5F
1.80
Refrigerant Type
R-454B

Eligibility

Rebates and certifications

Mass Save QPL
Yes
ENERGY STAR Certified
Yes
ENERGY STAR Cold Climate Certified
Yes

Explore your options

Similar systems to compare

Scroll horizontally or use the arrow keys to explore.

Same cooling capacity

Trane

Split-system heat pump

5TWR7024A1 — Trane AHRI 216763342

AHRI 216763342

Indoor model / pattern
5PX*B004AS3
Furnace model / pattern
L9X1A050U3VSA
Cooling · BTU/h
22,800
SEER2
17.10
HSPF2
8.70

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.70 vs. 10.00
  • Lower heating capacity at 17°F: 15,700 BTU/h.
  • Lower heating capacity at 5°F: 17,600 BTU/h.
View AHRI
Same cooling capacity

Trane

Split-system heat pump

5TWX7024A1 — Trane AHRI 216764112

AHRI 216764112

Indoor model / pattern
5PX*B004AS3
Furnace model / pattern
L9X1A050U3VSA
Cooling · BTU/h
22,800
SEER2
17.10
HSPF2
8.70

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.70 vs. 10.00
  • Lower heating capacity at 17°F: 15,700 BTU/h.
  • Lower heating capacity at 5°F: 17,600 BTU/h.
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27VNA324A*030* — Carrier AHRI 217624547

AHRI 217624547

Indoor model / pattern
CSAH*3612AM*+UI
Furnace model / pattern
58TN*B070C14**12
Cooling · BTU/h
22,800
SEER2
20.00
HSPF2
9.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 9.50 vs. 10.00
View AHRI
Same cooling capacity

Carrier

Split-system heat pump

27VNA024A*030* — Carrier AHRI 215683573

AHRI 215683573

Indoor model / pattern
CAA**2414AM*+UI
Furnace model / pattern
58TN*B070C14**12
Cooling · BTU/h
22,800
SEER2
17.00
HSPF2
9.00

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 9.00 vs. 10.00
  • Lower heating capacity at 5°F: 16,900 BTU/h.
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

EL21KLV-024-230A** — Lennox AHRI 217121537

AHRI 217121537

Indoor model / pattern
CK40[C,U]T-30A-**+TDR
Furnace model / pattern
EL280UH045E36A*
Cooling · BTU/h
22,800
SEER2
19.50
HSPF2
9.80

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 9.80 vs. 10.00
  • Lower heating capacity at 5°F: 17,300 BTU/h.
View AHRI
Same cooling capacity

Lennox

Split-system heat pump

SL22KLV-024-230A** — Lennox AHRI 218073776

AHRI 218073776

Indoor model / pattern
CK40[C,U]T-36C-**+TDR
Furnace model / pattern
SLP99UH090XV36C*
Cooling · BTU/h
22,800
SEER2
19.00
HSPF2
8.50

Cooling capacity (listed) · HSPF2 Region IV

Same cooling capacitySimilar cooling capacity.Lower HSPF2 (Region IV): 8.50 vs. 10.00
View AHRI

Side by side

See the differences

Your current system and up to two alternatives. Scroll the table to see every system.

Comparison does not confirm installation compatibility, availability, or current incentive eligibility. Unknown and qualified source values are not treated as zero.

Our Services

Showing services from our catalog

Brands We Service

Popular cities

Service Areas